Sudden movement of the machine can cause injury to persons on or near the machine. To prevent possible injury, perform the procedure that follows before testing and adjusting the water spray system. |
Personal injury or death can result from escaping fluid under pressure. Escaping fluid under pressure, even a very small pin-hole size leak, can penetrate body tissue and cause serious injury and possible death. If fluid is injected into your skin, it must be treated by a doctor familiar with this type of injury. Always use a board or cardboard when checking for a leak. |
Optimum efficiency in the water spray system occurs when 100% coverage by the drum is achieved. The following adjustments can improve the coverage by the drum.
- In order to change the direction of the spray, loosen four clamps (1) and rotate spray bar (3) .
Illustration 1 | g00596265 |
Area Of The Water Tank (1) Clamp. (2) Nozzle. (3) Spray bar. |
- The adjustment is made at the end of the nozzle (2). Use a standard flat screwdriver blade for the adjustment. In order to adjust the radial direction of the water spray, turn nozzle (2) .
Note: Coverage by the water spray is affected by the cleanliness of the nozzles (2). High flow nozzles are available for hot, dry, windy conditions.