Use the Caterpillar Monitoring System or the Caterpillar Electronic Technician in order to determine the service codes for the power train ECM. After determining the service codes, refer to the corresponding test procedure for more information. Perform the procedure that corresponds to the service code (CID and FMI). The following table is a list of possible service codes for the ECM.
Table 1
Service Codes For Transmission ECM (MID No. 081) (1)     |
For troubleshooting, see the procedure with the same CID And FMI No.     |
CID / FMI     |
Description     |
CID 0147 Lockup Clutch Pressure Sensor     |
FMI 03     |
Open circuit, or voltage above normal or shorted high     |
FMI 04     |
Short to ground     |
CID 0168 System Voltage     |
FMI 01     |
Voltage below normal.     |
CID 0190 Engine Speed Sensor     |
FMI 02     |
Data erratic, intermittent or incorrect.     |
CID 0444 Start Relay     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0468 Brake Pedal Position Sensor     |
FMI 03     |
Open circuit, or shorted high.     |
FMI 04     |
Short to ground.     |
CID 0615 Articulation Angle Sensor     |
FMI 03     |
Open circuit, or shorted high.     |
FMI 04     |
Short to ground.     |
CID 0637 Backup Alarm     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 06     |
Short to ground.     |
CID 0641 Transmission Solenoid #1     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0642 Transmission Solenoid #2     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0643 Transmission Solenoid #3     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0644 Transmission Solenoid #4     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0645 Transmission Solenoid #5     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0646 Transmission Solenoid #6     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0668 Shift Lever     |
FMI 02     |
Data erratic, intermittent, or incorrect.     |
FMI 03     |
Open circuit, or voltage above normal or shorted high.     |
CID 0672 Torque Converter Speed Sensor     |
FMI 02     |
Data erratic, intermittent, or incorrect.     |
CID 0701 Transmission Speed Sensor     |
FMI 02     |
Data erratic, intermittent, or incorrect.     |
CID 0709 Lockup Clutch Solenoid     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0737 Neutralizer Pedal Position Sensor     |
FMI 03     |
Open circuit, shorted high.     |
FMI 04     |
Short to ground.     |
CID 0738 Ripper Position Sensor     |
FMI 03     |
Open circuit, or shorted high.     |
FMI 04     |
Short to ground.     |
CID 0739 Differential Lock Lamp     |
FMI 03     |
Open circuit, or voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0740 Differential Lock Solenoid     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0741 Converter Drive Lamp     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
CID 0742 Brake Lamp Relay     |
FMI 03     |
Voltage above normal or shorted high.     |
FMI 05     |
Open circuit.     |
FMI 06     |
Short to ground.     |
( 1 ) | For the Transmission ECM, the MID is 081. This table pertains only to faults with a MID of 081. |