The circuit breaker panel is located in the operator compartment. The circuit breaker panel also contains fuses.
Show/hide table
|
|
|
Illustration 1 | g00611419 |
The circuit breakers protect the electrical system from damage.
Reset the circuit breaker if the circuit breaker trips. Push in the button in order to reset the circuit breaker. If the electrical system is working properly, the button will remain depressed. If the button does not remain depressed and the circuit breaker trips soon after being reset, check the appropriate electrical circuit. Repair the electrical circuit, if necessary.
Show/hide table
| Headlamps - 15 amp |
The circuit breaker for the headlamp is located behind the panel. The circuit breaker resets automatically when the fault is corrected.
Show/hide table
| Heater/Air Conditioner (1) - 15 amp |
Show/hide table
| Start Switch (2) - 10 amp |
Circuit Breakers for the Alternator and for the Battery
Show/hide table
|
|
|
Illustration 2 | g00655109 |
The circuit breakers for the alternator and for the battery are located under the engine hood on the front right side of the engine compartment. Circuit breaker (3) for the battery protects the battery from a dead short. Circuit breaker (4) for the alternator protects the alternator from a power surge. Reset the circuit breaker if the breaker trips. Push in the button in order to reset the circuit. If the button does not remain depressed and the circuit breaker trips soon after being reset, check the appropriate electrical circuit. Repair the electrical circuit, if necessary.
Show/hide table
| Battery (3) |
Show/hide table
| Alternator (4) |