Usage:
D8K ( 66V, 76V, 77V ),
D9H ( 90V ) Tractors;
583K ( 78V ),
594H ( 96V ) Pipelayers
Description of Change: Different water temperature regulators are used in the water lines groups on the above models. The new water temperature regulators open at a temperature of 80°C (175°F). The former regulators opened at a temperature of 74°C (165°F). The temperature at which the regulators open was increased to lower the amount of condensation in the cylinders. When a high sulfur fuel is used, condensation causes acid which increases the rate of wear on piston rings, cylinder liners and valve guides.
Adaptable As: The new 9N2894 Water Temperature Regulator is a direct replacement for the former 9S9160 Water Temperature Regulator. Two regulators are used per machine.
NOTICE |
---|
Do not use regulators with different opening temperatures in an engine. Make sure the two regulators are the same.
|