- Engine
- G3516H (S/N: ME31-UP)
- Power Module
- PM3516 (S/N: NBR1-UP)
- PMG3516 (S/N: JKK1-UP)
- XQC1600 (S/N: ME21-UP; N1M1-UP)
- PMG3516 (S/N: JKK1-UP)
The following changes are now available for the products within the listed serial numbers.
The new firmware is for the DEIF AGC-4 392-8122 Controller.
The new firmware will eliminate the use of a physical magnetic pick-up to monitor engine speed when controlling the power module in a dead bus paralleling mode.
The new firmware for the control allows engine speed to be read from the ADEM/EMCP4 via the CAN data link.
Go to DEIF.com to acquire the new firmware, agc4_4008v4670 and above.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility. |