323F LN Excavator Machine Systems Caterpillar


Solenoid Valve (Proportional Reducing) - Calibrate - Negative Flow Control

Usage:

323F SA FA2

Introduction

Negative flow control pressure flows to the regulators at the drive pump and the idler pump to control the output flow of the pumps. The proportional reducing valve for negative flow control regulates the amount of pilot pressure from the pilot pump and signal oil pressure from the main control valve that flows into the regulators of the main pumps. The proportional reducing valves for negative flow control are controlled by the machine ECM.

Required Tools



Illustration 1g01623868
Tooling group "B"
198-4240 Digital Pressure Indicator Gp

Table 1
Tool  Item  Part Number  Description  Qty 
198-4240  Digital Pressure Indicator Gp   
  B1  198-4234  Indicator 
B2 198-4237  Pressure Sensor 3445 kPa (500 psi) 
B3 198-4236  Extension Cable 

Machine Preparation

  1. The following procedures must be completed before performing the calibration.

    • Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.

    • Calibrate the power shift pressure. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)" for the machine.

  2. Position the machine on level ground and stop the engine.

  3. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".


    Illustration 2g06255387
    Pressure taps for the proportional reducing valves (negative flow control)
    (1) Pressure tap for "NFC1"
    (2) Pressure tap for "NFC2"

  4. Connect two 3445 kPa (500 psi) pressure sensors to the pressure taps on the proportional reducing valves for negative flow control. The proportional reducing valve pressure taps for negative flow control of the drive pump and idler pump are located in the pump compartment.

  5. Start the engine.

  6. Increase the hydraulic oil temperature to 55° ± 5°C (131° ± 9°F).

  7. Place the hydraulic activation lever in the UNLOCK position.

Calibration Procedure

Note: This procedure is typical for both proportional reducing valves for negative flow control.

  1. Enter the service mode. Input the password "9992".


    Illustration 3g02540004

  2. Select "Main Pump Flow Limit" from the "Calibrations" menu.


    Illustration 4g02540097

  3. Select "NFC (Press Gauge Method)" for the appropriate valve from the "Main Pump Flow Limit" menu.

  4. Press the OK key to start the calibration. The engine RPM will automatically increase to the equivalence of engine speed dial 10.

  5. Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.

  6. Move the joystick for STICK OUT to the full out position and hold the joystick in this position.

    Note: If necessary, a BOOM RAISE function may be performed in place of STICK OUT.



    Illustration 5g02540199

  7. Use the arrows to adjust the pressure until the pressure reading for the negative flow control valve is at 1500 ± 50 kPa (218 ± 7 psi). Press the OK key.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".

  8. Move the joystick for STICK OUT to the NEUTRAL position.

  9. Confirm notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.

  10. Move the joystick for STICK OUT to the full out position and hold the joystick in this position.

    Note: If necessary, a BOOM RAISE function may be performed in place of STICK OUT.



    Illustration 6g02540267

  11. Use the arrows to adjust the pressure until the pressure reading for the negative flow control valve is at 3000 ± 50 kPa (435 ± 7 psi). Press the OK key.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".

  12. Move the joystick for STICK OUT to the NEUTRAL position.


    Illustration 7g02540302

  13. If calibration was successful and no errors occurred, the display will indicate that the calibration is complete.


    Illustration 8g02540758

  14. The "Error" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.

Caterpillar Information System:

323F LN Excavator Machine Systems Solenoid Valve (Proportional Reducing) - Calibrate - Power Shift Pressure
797F Off-Highway Truck Air Dryer Desiccant - Replace
C32 Generator Set Engines Vibration Damper - Check
C32 Generator Set Engines Engine Oil Pressure - Test
797F Off-Highway Truck Air Dryer - Check
C32 Generator Set Engines Basic Engine
797F Off-Highway Truck Magnetic Plug (High Pressure Fuel Pump) - Check
C32 Generator Set Engines Cooling System
C32 Generator Set Engines Lubrication System
C32 Generator Set Engines Air Inlet and Exhaust System
C7.1 Commercial Marine Engine Engine Oil Cooler - Inspect
C32 Generator Set Engines Fuel System
326F Excavator Machine System Relief Valve (Main) - Test and Adjust
326F Excavator Machine System Relief Valve (Line) - Test and Adjust
336, 336 GC and 340 Excavator Systems Main Pump (Flow) - Test - Hydraulic Power
323F LN Excavator Machine Systems Relief Valve (Swing) - Test and Adjust
323F LN Excavator Machine Systems Main Pump (Flow) - Test - Hydraulic Power
323F LN Excavator Machine Systems Pump Control (Output Flow) - Test - One Pump Calibration (Optional Test)
336 Excavators (Powered by C9.3 Tier 4 Engine) Engine Supplement Electronic Control Module - Remove and Install
Improved Crankshafts are Now Used on Certain Cat® Engines {1202} Improved Crankshafts are Now Used on Certain Cat® Engines {1202}
Rain Water May Enter in Muffler/Silencers on Certain 3516 Power Modules {1062} Rain Water May Enter in Muffler/Silencers on Certain 3516 Power Modules {1062}
797F Off-Highway Truck Towing the Machine
C7.1 Commercial Marine Engine Cooling System
Procedure to Selection of Parts for Right Turbocharger to Clean Emissions Module (CEM) Inlet for Certain C175 Engines {1052, 1061, 108D} Procedure to Selection of Parts for Right Turbocharger to Clean Emissions Module (CEM) Inlet for Certain C175 Engines {1052, 1061, 108D}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.