NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products. Dispose of all fluids according to local regulations and mandates. |
- Remove insulation (1) from the separator assembly.
Show/hide table
Illustration 2 g06300736 - Disconnect line assembly (2).
Show/hide table
Illustration 3 g06300738 - Disconnect line assembly (5) and loosen clamp (3), clamp (4), and clamp (6).
Show/hide table
Illustration 4 g06300740 - Remove bolt (9). Remove hose (7), and hose (8).
Show/hide table
Illustration 5 g06300742 - Remove nuts (10), cover (11), and the four spacers.
Show/hide table
Illustration 6 g06300746 - Remove bolts (12) and fumes disposal cover (13).
Show/hide table
Illustration 7 g06300750 - Remove separator assembly (14).
- Repeat Steps 2 through 7 for the remaining separator assemblies
Illustration 1 | g06300733 |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Install separator assemblies (14) in the reverse order of removal.
Note: Ensure that the foam damper pads are installed with the separator assemblies.