Do not operate the generator if the windings are wet. If the generator is operated when the windings are wet, damage can occur due to insulation breakdown.


------ WARNING! ------

Personal injury or death can result from improper troubleshooting and repair procedures.

The following troubleshooting and repair procedures should only be performed by qualified personnel familiar with this equipment.

----------------------

Refer to Safety Section, "Generator Isolating for Maintenance" for information regarding the procedure to isolate the generator safely.

When moisture is present or when moisture is suspected in a generator, the generator must be dried before being energized.

If the drying procedure does not restore the insulation resistance to an acceptable value, the winding should be reconditioned.

Drying Methods

For drying the generator, refer to Special Instruction, SEHS9124, "Cleaning and Drying of the Generator".


NOTICE

Do not allow the winding temperature to exceed 85 °C (185.0 °F). Temperatures that are greater than 85 °C (185.0 °F) will damage the winding insulation.


Oven Method

Place the entire generator inside a forced air drying oven for 4 hours at 65 °C (149 °F).


NOTICE

Use a forced air type oven rather than a radiant type oven.

Radiant type ovens can cause localized overheating.


Controlled Current Method




Illustration 1g00614674

External Power Source Circuit

(1) Battery (12 VDC)

(2) Rheostat (15 ohm 25 W)

(3) Exciter Field (Stator "L1")

Table 1
TOOLS NEEDED    
Quantity     Part Number     Description    
1     225-8266     Clamp-on ammeter (1200 A)    
1         External power source circuit    

Heat can be used in order to dry the generator windings. This heat can be created by allowing a controlled current to flow through the generator. No high voltages are generated during the following procedure. Therefore, insulation breakdown will not occur.

  1. Make an external power source. Refer to Illustration 1.

  1. Disconnect F1+ from the voltage regulator. Disconnect F2- from the voltage regulator. Disconnect the generator load. Connect the generator output leads T0, T1, T2, and T3 together. Install the clamp-on ammeter to generator output lead T1.

    Note: When the line current is measured on multiple lead units, measure the current in each conductor per phase. The currents can then be added.

  1. Refer to Illustration 1. Adjust the rheostat to the maximum resistance value. Connect the external power source to wires F1+ and F2-.

  1. Start the generator set. Run the generator set at Idle speed.


    NOTICE

    Do not exceed the rated phase current that is listed on the generator nameplate. Exceeding the rated phase current will easily damage the generator windings.


  1. Monitor the phase current. In order to maintain use of the circuits for the protection of safety, use the "EMCP 4" control panel to increase the engine rpm gradually. Increase the engine rpm until one of the following conditions are met:

    • The rated phase current is obtained.

    • The full generator set speed is obtained.

  1. If more phase current is necessary, slowly turn the rheostat. Turn the rheostat until the rated phase current is reached.

  1. On an hourly basis, stop the drying procedure. Check the insulation resistance. Repeat the above steps until the insulation resistance is acceptable.

Guidelines for Space Heaters

  1. Energize the space heaters when the generator is not operating.

  1. Maintain the winding temperature at least 5 °C (9 °F) over the ambient temperature. In order to maintain the desired temperature in some conditions, a supplemental heat source or temporary covers may be required.

  1. Check that the insulation resistance until the resistance is acceptable.

Note: For more information on drying methods, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".

Caterpillar Information System:

797F and 797F XQ Off-Highway Truck/Tractor Braking System Valve (Unloader)
G3500H 60Hz Generator Sets Coolant (NGEC) - Change
G3500 Engines System Pressure Release
G3500H 60Hz Generator Sets General Maintenance Information
New Power Converter Is Now Available On Certain Off-Highway Truck/Tractors and Track-Type Tractors {1408, 7301} New Power Converter Is Now Available On Certain Off-Highway Truck/Tractors and Track-Type Tractors {1408, 7301}
G3500H 60Hz Generator Sets Emergency Stopping
Procedure to Upgrade EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.3{4490} Procedure to Upgrade EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.3{4490}
G3500H 60Hz Generator Sets Sensors and Electrical Components
G3500H 60Hz Generator Sets Product Installation
3516C Locomotive Engines Selective Catalytic Reduction SCR Module Differential Pressure Is High
2014/01/17 New Rotocoils Are Used on Certain G3500 Engines {1100}
3516C Locomotive Engines Selective Catalytic Reduction DEF Tank Level Is Low
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Generator Bearing - Inspect
G3512 Generator Set Generator Bearing - Lubricate
G3500H 60Hz Generator Sets Generator Set Alignment - Check - Generator Sets
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Generator Winding Insulation - Test
G3500H 60Hz Generator Sets Rotating Rectifier - Check
C4.4 Marine Generator Set Safety Messages
303.5E2 CR, 304E2 CR, 304.5E2 XTC, 305E2 CR and 305.5E2 CR Mini Hydraulic Excavators Hydraulic System Relief Valve (Line)
2013/12/18 New Insulation Design Is Used On SCR Retrofit Aftertreatment Systems {1067}
2013/12/23 A New Oil Pump and Tube Assemblies Are Now Used for Certain C9 Engines {1304, 1315}
C27 and C32 Engines for Caterpillar Built Machines Engine Oil Filter Base - Remove and Install
330F MHPU Mobile Hydraulic Power Unit Machine System Cab Lighting
G3600 A4 Engines Engine Cranks but Does Not Start
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.