950K and 962K Wheel Loaders Electrohydraulic System Caterpillar


MID 082 - CID 0600 - FMI 04

Usage:

950K FER
Conditions Which Generate This Code:


Illustration 1g02674336
Connections of the Hydraulic Oil Temperature Sensor

This diagnostic code is associated with the Hydraulic Oil Temperature Sensor. The FMI 04 means that the Implement ECM has determined that the voltage of the sensor signal circuit is below normal.

The sensor resistance range is 33,650 ohms at −40° C (−40° F) to 18.6 ohms at 150° C (302° F). The following table indicates the approximate sensor resistance between contacts 1 and 2 at different sample temperatures.

Table 1
Hydraulic Oil Temperature Sensor Resistance at Indicated Temperatures 
Oil Temperature  Resistance (Ohms) 
0° C (32° F)  3268 
20° C (68° F)  1250 
40° C (104° F)  532 
70° C (158° F)  175 
80° C (176° F)  126 
90° C (194° F)  92 
100° C (212° F)  68 
115° C (239° F)  45 
125° C (257° F)  34 
130° C (266° F)  30 

The possible causes of this diagnostic code are listed below:

  • The signal circuit for the sensor is shorted to ground.

  • The sensor has failed.

  • The machine ECM has failed. This condition is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, that all connections are secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected.

Test Step 1. CHECK THE SENSOR

  1. Turn the disconnect switch and the key start switch to the ON position.

  2. Ensure that the diagnostic code is active.

  3. Observe the status of the diagnostic code. Disconnect the sensor from the machine harness.

Expected Result:

The CID 0600 FMI 04 diagnostic code changes to a CID 0600 FMI 03 diagnostic code when the sensor is disconnected from the machine harness.

Results:

  • YES - The CID 0600 FMI 04 diagnostic code changes to a CID 0600 FMI 03 diagnostic code when the sensor is disconnected. The sensor has failed.

    Repair: The sensor is causing the problem. Replace the temperature sensor.

    STOP

  • NO - Disconnecting the sensor from the machine harness did not change the status for the active diagnostic code. The CID 0600 FMI 04 diagnostic code is still active. The sensor is not causing the problem. Proceed to Test Step 2.

Test Step 2. CHECK THE SENSOR CIRCUIT FOR A SHORT

The sensor remains disconnected from the machine harness.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  2. Disconnect the machine harness connector J1 and J2 from the Implement ECM.

  3. At the machine harness connector for the ECM, measure the resistance from the signal contact J1-29 (wire 442-GY(Grey)) to frame ground. Measure the resistance from the signal contact J1-29 (wire 442-GY(Grey)) to all of the contacts that are used in the machine harness connectors for the Implement ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - One or more resistance measurements are less than 5000 ohms. There is a short in the machine harness.

    Repair: The short is between signal wire 442-GY(Grey) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK THE OPERATION OF THE ECM

The key start switch and the disconnect switch remain in the OFF position. The machine harness connector for the sensor and the ECM connectors remain disconnected.

  1. At the machine harness connector of the ECM J1, use a 151-6320 Removal Tool to remove the signal wire of the sensor 442-GY(Grey) and the socket at contact J1-29 from the harness connector.

  2. Reconnect the machine harness connectors J1 and J2 to the ECM.

  3. Turn the key start switch and the disconnect switch to the ON position.

  4. Observe the status of the CID 0600 FMI 04 diagnostic code.

Expected Result:

The CID 0600 FMI 04 diagnostic code is no longer active. A CID 0600 FMI 03 diagnostic code becomes active when the wire 442-GY(Grey) at J1-29 is disconnected from the ECM connector.

Results:

  • YES - The CID 0600 FMI 04 diagnostic code is no longer active. A CID 0600 FMI 03 diagnostic code becomes active when the wire 442-GY(Grey) at J1-29 is disconnected from the ECM connector. The ECM has responded correctly to the open circuit condition in the sensor circuit. Most likely cause of the problem is not the ECM. Reinstall the disconnected sensor signal wire back into the correct spot in the ECM connector before proceeding to the next test step. Proceed to Test Step 4.

  • NO - The CID 0600 FMI 04 diagnostic code remains active. The status of the active diagnostic code does not change when the sensor wire is disconnected from the ECM.

    Repair: The ECM has not responded correctly to the open condition in the sensor circuit. The operation of the ECM is not correct.

    Prior to replacing an ECM, always contact the Technical Communicator at your dealership for possible consultation with Caterpillar. This consultation may effect repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 4. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors. Clean the contacts of the harness connectors. Check the wires for damage to the insulation that can be caused by excessive heat, battery acid, or chafing.

  2. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  3. Reconnect all harness connectors. Make sure that the connectors are fully seated and locked.

  4. Turn the disconnect switch and the key start switch to the ON position.

  5. Operate the machine.

  6. Check the status of the CID 0600 FMI 04 diagnostic code.

Expected Result:

The CID 0600 FMI 04 diagnostic code is active.

Results:

  • YES - The CID 0600 FMI 04 diagnostic code is active. The problem has not been corrected.

    Repair: If available, perform a Wiggle Test on the sensor circuit of the machine wiring harness with the Caterpillar Electronic Technician (CAT ET). The Wiggle Test can be used to detect the following in the machine wiring harness:

    If the cause of the problem is not found, the ECM may have failed.

    Prior to replacing an ECM, always contact the Technical Communicator at your dealership for possible consultation with Caterpillar. This consultation may effect repair time. If the cause of the diagnostic code is not found, replace the ECM that has activated the diagnostic code. See the Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0600 FMI 04 diagnostic code is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

2011/10/27 Improved Waste Handling Arrangements (If Equipped) are Now Available for Certain Track-Type Tractors {7000}
950K and 962K Wheel Loaders Electrohydraulic System MID 082 - CID 0600 - FMI 03
C4.4 Engines for Caterpillar Built Machines Inlet Manifold Temperature Sensor
C4.4 Engines for Caterpillar Built Machines Alternator Belt
D11T Track-Type Tractor Restricted Visibility
950K and 962K Wheel Loaders Electrohydraulic System MID 082 - CID 0494 - FMI 13
C4.4 Engines for Caterpillar Built Machines Idler Pulley - Flat Idler Pulley
D9T Track-Type Tractor Power Train Brake Control Valve - Install
950K and 962K Wheel Loaders Electrohydraulic System MID 082 - CID 0494 - FMI 06
C4.4 Engines for Caterpillar Built Machines Idler Pulley - Grooved Idler Pulley
C4.4 Engines for Caterpillar Built Machines Belt Tensioner
2011/08/17 An Improved Shunt Tank Vent Line Routing Is Now Being Used on Certain 966H and 972H Medium Wheel Loaders {1377, 1380}
C4.4 Engines for Caterpillar Built Machines Boost Pressure Sensor
2011/10/03 Improved Waste Handling Arrangement (If Equipped) is Now Available for Certain Track-Type Tractors {7000}
C4.4 Engines for Caterpillar Built Machines Engine Oil Pressure Sensor
C4.4 Engines for Caterpillar Built Machines Coolant Temperature Sensor
C4.4 Engines for Caterpillar Built Machines Crankshaft Position Sensor
C4.4 Engines for Caterpillar Built Machines Camshaft Position Sensor
C4.4 Engines for Caterpillar Built Machines Atmospheric Pressure Sensor
950K and 962K Wheel Loaders Electrohydraulic System MID 082 - CID 0779 - FMI 03
950K and 962K Wheel Loaders Electrohydraulic System MID 082 - CID 0779 - FMI 04
854K Wheel Dozer Field Assembly Procedure {7000, 7960} 854K Wheel Dozer Field Assembly Procedure {7000, 7960}
950K and 962K Wheel Loaders Electrohydraulic System MID 082 - CID 0800 - FMI 09
950K and 962K Wheel Loaders Electrohydraulic System MID 082 - CID 0800 - FMI 14
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.