Removal Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
Sulfuric Acid Burn Hazard, may cause serious personal injury. The clean gas induction (CGI) pressure sensor may contain a small amount of sulfuric acid. The use of fuel with sulfur levels greater than 15 ppm may increase the amount of sulfuric acid formed. The sulfuric acid may spill from the CGI cooler during service of the engine and may travel to other downstream components. The sulfuric acid will burn the eyes, skin, and clothing on contact. Always wear the appropriate personal protective equipment (PPE) that is noted on a material safety data sheet (MSDS) for sulfuric acid. Always follow the directions for first aid that are noted on a material safety data sheet (MSDS) for sulfuric acid. |
- Disconnect harness assembly (1) . Disconnect hoses (2) .
Illustration 1 | g01297334 |
- Remove bolt (3) .
- Remove clean gas induction pressure sensor (4) .
Installation Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
Sulfuric Acid Burn Hazard, may cause serious personal injury. The clean gas induction (CGI) pressure sensor may contain a small amount of sulfuric acid. The use of fuel with sulfur levels greater than 15 ppm may increase the amount of sulfuric acid formed. The sulfuric acid may spill from the CGI cooler during service of the engine and may travel to other downstream components. The sulfuric acid will burn the eyes, skin, and clothing on contact. Always wear the appropriate personal protective equipment (PPE) that is noted on a material safety data sheet (MSDS) for sulfuric acid. Always follow the directions for first aid that are noted on a material safety data sheet (MSDS) for sulfuric acid. |
- Install clean gas induction pressure sensor (4) and install bolt (3) .
Illustration 2 | g01297334 |
- Connect hoses (2) . Connect harness assembly (1) .