Removal Procedure
Start By:
- Release system pressure. Refer to Disassembly and Assembly, "Hydraulic System Pressure - Release".
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contamination of the hydraulic system with foreign material will reduce the service life of the hydraulic system components. To prevent contaminants from entering the hydraulic system, always plug or cap the lines, fittings, or hoses as they are disconnected. Cover any disassembled components and clean them properly before assembly. Clean the hydraulic system properly after any major component exchange or especially after a component failure, to remove any contamination. |
- Remove bolts (1). Remove bypass valve (2) from the hydraulic tank.
Illustration 1 | g01265361 |
Installation Procedure
- Position bypass valve (2) and install bolts (1) onto the hydraulic tank.
Illustration 2 | g01265361 |