Removal Procedure
Personal injury can result from contact with refrigerant. This system is under pressure at all times, engine running or not. Heat should never be applied to a charged system. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury. Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant. Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area. Personal injury or death can result from inhaling refrigerant through a lit cigarette. Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death. Do not smoke when servicing air conditioners or wherever refrigerant gas may be present. Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel either away from the machine or where they can be seen. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Note: For charging and evacuating the air conditioner system, refer to Air Conditioning and Heating Service Manual, SENR3334.
- Evacuate the air conditioner system.
- Open access door assembly (1) that is located on the left fender.
Illustration 1 | g00617472 |
- Remove four bolts (2) and tray assembly (3) .
- Disconnect two air conditioner quick disconnects (6) from air conditioner dryer (5) .
Illustration 2 | g00617356 |
- Remove the bolt and clip (4). Remove air conditioner dryer (5) .
Installation Procedure
- Install air conditioner dryer (5) and install the bolt and clip (4) .
Illustration 3 | g00617356 |
- Connect two air conditioner quick disconnects (6) to air conditioner dryer (5) .
- Install tray assembly (3). Install four bolts (2) .
Illustration 4 | g00617472 |
- Close access door assembly (1) .
- Charge the air conditioner system.
- Refer to Operation and Maintenance Manual, "Lubricant Viscosities and Refill Capacities" for all fluid capacities and filling procedures.