Removal Procedure
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Disconnect harness assembly (1) .
Illustration 1 | g00993096 |
Typical example |
- Remove fuel temperature sensor (2) and the O-ring seal.
Installation Procedure
- Install the O-ring seal on the fuel temperature sensor.
Illustration 2 | g00993096 |
Typical example |
Note: Check the condition of the O-ring seal. If the O-ring seal is worn or damaged, use a new part for replacement.
- Install fuel temperature sensor (2). Tighten the fuel temperature sensor to a torque of 20 ± 5 N·m (15 ± 4 lb ft).
- Connect harness assembly (1) .