SPS343 Skid Mounted Pumper Caterpillar


Junction Box

Usage:

SPS343 8ZZ
The junction box is the central location for the electrical wiring of the pumper. The junction box also contains two air solenoid valves that control the following components:

  • Air shutoffs

  • Packing lube tank

  • Driveline brake




Illustration 1g00820277

(1) "MAIN POWER DISCONNECT" Switch

(2) Service Hour Meter

(3) "WARNING" Light

(4) "PUMP STROKE" Counter

(5) "FUEL CUTOFF SWITCH"

(6) Remote Cable Connector

"MAIN POWER DISCONNECT" Switch

The "MAIN POWER DISCONNECT" Switch (1) is a two-position toggle switch. The switch controls the power to the electrical system.

Service Hour Meter

The Service Hour Meter (2) indicates the total operating hours of the deck engine. Use the display to determine the service hour maintenance intervals.

"WARNING" Light

The "WARNING" Light (3) is a red light. The light indicates a fault condition of the deck engine. The Caterpillar Electronic Technician (ET) can be used to troubleshoot problems that are related to the deck engine. Refer to Troubleshooting for additional information.

"PUMP STROKE" Counter

The "PUMP STROKE" Counter (4) provides a running total of pump strokes for pump life recording and determination of pump packing replacement intervals.

"FUEL CUTOFF SWITCH"

The "FUEL CUTOFF SWITCH" (5) is a two-position toggle switch. Operation of the switch will immediately shut off the fuel supply to the deck engine. This will result in a shutdown of the system. To activate the switch, the red switch guard must be lifted. The switch must then be moved to the opposite keyway. A switch guard is necessary in order to prevent an accidental shutdown.

Remote Cable Connector

The Remote Cable Connector (6) is a connector that connects to one end of the 38 m (125 ft) remote control cable. The other end of the cable connects to the Universal Remote Control Console.

Caterpillar Information System:

2001/10/01 Oil Condition Will Affect The Operation of The HEUI Fuel System {1348, 1714}
Automatic Transfer Switches CTS, CTSD Series Functional Test of the Transfer Switch
SPT343 Truck Mounted Pumper Universal Remote Control Console
C0.5, C0.7, C1.1/3011C, C1.5/3013C, C1.6 and C2.2/3024C/3024CT Industrial Engines and Engines for Caterpillar Built Machines Engine Oil Pressure Switch
SPS343 Skid Mounted Pumper Reference Material
Automatic Transfer Switches CTG, CTGD Series Transfer Switch - Test
Automatic Transfer Switches CTG, CTGD Series Transfer Mechanism - Lubricate
G3408C and G3412C Engines Measuring Inlet Manifold Temperature
HDB Series and M1 Series Heavy Duty Brushless Alternators Charging System
G3406 Engine Restriction of Air Inlet and Exhaust
G3408C and G3412C Engines Engine Speed/Timing Sensor
G3408C and G3412C Engines Detonation Sensor
3024C Engine for Caterpillar Built Machines Engine Oil Relief Valve
3126 Truck Engine Military Cylinder Head - Remove
3126 Truck Engine Military Cylinder Head - Install
Generator Set Start Module System Schematic
3054, 3054B and 3056 Marine Engines Maintenance Interval Schedule - 3054B Marine Naturally Aspirated
Automatic Transfer Switches CTS, CTSD Series Engine Control Connections of the Controller
G3408C and G3412C Engines Crankshaft Position for Valve Lash Setting
2001/09/01 Corrections To Operation and Maintenance Manual, SEBU6883-03, "G3408C and G3412C Engines" {7450}
G3408C and G3412C Engines Crankshaft Position for Valve Lash Setting
3126B Industrial Engines System Configuration Parameters
C0.5, C0.7, C1.1/3011C, C1.5/3013C, C1.6 and C2.2/3024C/3024CT Industrial Engines and Engines for Caterpillar Built Machines Fuel Shutoff Solenoid
G3408C and G3412C Engines Carburetor - Adjust
Back to top