Programmable Relay Control Module (PRCM) Caterpillar


PRCM CID 0590 - FMI 09

Usage:

3516B 1NW
Conditions Which Generate This Code:

The CID 0590 FMI 09 failure means that the engine electronic control module has stopped responding to the periodic requests for information from the PRCM. The PRCM detects this condition when there is a loss of the data signal on the CAT data link.

Note: The PRCM will not communicate properly with the engine ECM if the data link cable exceeds 30.5 m (100 ft). See Specifications, "Electrical" for additional information.

Note: The PRCM is capable of being programmed in order to treat diagnostic codes for the ECM in one of two ways.

  • Setpoint P03 is 1. The PRCM will display CID 0590 FMI 09 and the PRCM will display CID 0248 FMI 11. The diagnostic codes are displayed as being active. When the diagnostic codes are inactive, the diagnostic codes will NOT be logged.

  • Setpoint P03 is 2. The PRCM will display CID 0590 FMI 09 and the PRCM will display CID 0248 FMI 11. The diagnostic codes are displayed as being active. When the diagnostic codes are inactive, the diagnostic codes will be logged.

Test Step 1. CHECK THE CAT DATA LINK

  1. Disconnect the contacts 19 and 20 of the CAT data link from the PRCM.

  1. Disconnect the contacts 13 and 14 of the CAT data link from the ECM.

  1. Measure the resistance between contact 19 of the PRCM and contact 14 of the ECM.

  1. Measure the resistance between contact 20 of the PRCM and contact 13 of the ECM.

Expected Result:

The resistance for both measurements is less than 5 ohms.

Results:

  • OK - The resistance for both measurements is less than 5 ohms. The circuit is correct. The ECM has failed.

    Repair: It is unlikely that the ECM has failed. See Troubleshooting, SENR1003, "3500B EPG Engines"prior to replacing the ECM. Clear the diagnostic code from the fault log after troubleshooting is complete. The PRCM is usually programmed to treat a CID 590 diagnostic code as an "alarm fault".

    Stop.

  • NOT OK - The resistance for both measurements is greater than 5 ohms. The circuit is not correct.

    Repair: Repair the wiring of the CAT data link or replace the wiring of the CAT data link.Clear the diagnostic code from the fault log after troubleshooting is complete. The PRCM is usually programmed to treat a CID 590 diagnostic code as an "alarm fault".

    Stop.

Caterpillar Information System:

Programmable Relay Control Module (PRCM) PRCM CID 0483 - FMI 04
2000/07/01 Repair Kits For Engine Speed Sensors Are Now Available {1907, 1912}
Programmable Relay Control Module (PRCM) PRCM CID 0483 - FMI 03
Programmable Relay Control Module (PRCM) PRCM CID 0482 - FMI 04
Programmable Relay Control Module (PRCM) PRCM CID 0482 - FMI 03
Programmable Relay Control Module (PRCM) PRCM CID 0481 - FMI 04
Installation Of The 194-5339 Speed Sensor Gp and The 194-5340 Speed Sensor Gp Kits{1900, 1907} Installation Of The 194-5339 Speed Sensor Gp and The 194-5340 Speed Sensor Gp Kits{1900, 1907}
Programmable Relay Control Module (PRCM) PRCM CID 0481 - FMI 03
Programmable Relay Control Module (PRCM) PRCM CID 0480 - FMI 04
Programmable Relay Control Module (PRCM) PRCM CID 0480 - FMI 03
Programmable Relay Control Module (PRCM) PRCM CID 0479 - FMI 04
Programmable Relay Control Module (PRCM) PRCM CID 0479 - FMI 03
3126B and 3126E On-highway Engines 5 Volt Engine Pressure Sensor Supply Circuit - Test
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0190 - FMI 03
Electronic Modular Control Panel II+ (EMCP II+) Engine Does Not Shutdown (for PEEC Engines)
3500 Engines For Caterpillar Built Power Modules Aftercooler
Electronic Installation Guide{1000} Electronic Installation Guide{1000}
3500 Generator Set Engines Valve System Components
2000/11/01 Remanufactured Stanadyne Fuel Injection Pumps are Available for 3054 and 3056 Engines {1251}
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0248 - FMI 09 (for EUI Engines)
C11 and C15 Engines for Caterpillar Built Machines Can Not Reach Top Engine RPM
C-9 Engine for TK711, TK721, TK722, TK732, TK741, TK751, and TK752 Track Feller Bunchers Electronic Service Tool Will Not Communicate with ECM
PM3516 Power Modules Reference Material
C-10, C-12, C-15 and C-16 Industrial Engines Engine Cranks but Will Not Start
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.