3512B Petroleum Engines Caterpillar


ECM Voltage

Usage:

3512B 2AF
The ECM automatically warns the operator of low system voltage. The default settings that are programmed at the factory are listed in Table 1.

Table 1
Voltage Monitoring 
Parameter  Default Setting 
Warning setpoint  20 volts 
Warning delay  10 seconds 
Hysteresis  2 volts 
Security level  No required password 

If the voltage is below 20 volts for 10 seconds, a warning will occur. To deactivate the warning, the voltage must rise above 22 volts.

The setpoint can be programmed to a value between 20 and 30 volts.