Air Inlet Choke - Remove
Show/hide table
注意 |
---|
保持所有零件清洁无杂质。 杂质会造成快速磨损並縮短部件使用寿命。 |
注: 将开口盖上以防污染。
Show/hide table
图 1 | g00590678 |
- 卸下螺栓 (3),以便断开阻风门和阻风门执行器的连接件。
- 拧松操纵杆的螺栓。 从轴 (5) 上卸下操纵杆 (6)。
- 卸下八个螺栓 (2)。
- 卸下八个螺栓 (1)。
- 卸下壳体组件 (4) 和垫片。 检查密封垫有无损坏。 必要时更换密封垫。
Caterpillar Information System:
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 445 FMI 12 Run Relay Failed - Test
G3612 and G3616 Engines Junction Box (Hydrax) - Remove and Install
C9 On-Highway Truck Engines Unit Injector Hydraulic Pump - Remove
Generator Set Load Sensor Phasing - Adjust
3114, 3116 and 3126 Engines Alternator Noise
G3612 and G3616 Engines Hydraulic Tank (Hydrax) - Remove and Install
G3612 and G3616 Engines Hydraulic Oil Pump (Hydrax) - Remove and Install
3500B Engines Air Inlet Manifold - Remove and Install
G3612 and G3616 Engines Caterpillar Ignition System (CIS) Module - Remove and Install
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 444 FMI 12 Starting Motor Relay Failed - Test
G3612 and G3616 Engines Actuator (Hydrax) - Assemble
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 443 FMI 12 Crank Termination Relay Failed - Test
G3612 and G3616 Engines Air Inlet Choke - Disassemble
3114, 3116 and 3126 Engines Engine Misfires, Knocks, or Is Unstable (at Idle Only)
G3612 and G3616 Engines Air Inlet Choke - Assemble
G3612 and G3616 Engines Air Inlet Elbow - Remove and Install
3034 Industrial Engine Cold Weather Starting
3114, 3116 and 3126 Engines Engine Overspeeds on Start
G3612 and G3616 Engines Air Starting Motor - Disassemble
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 446 FMI 12 Air Shutoff Relay Failed - Test
SR4B Generators Generator - Install
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 447 FMI 12 Fuel Control Relay Failed - Test
3044C Industrial Engine Fuel Conservation Practices
G3612 and G3616 Engines Generator - Remove and Install