Usage:
5130 (7TJ, 5ZL),
5130B (4CS),
5230 (7LL) Excavators
Description of Change: A new magnet is used to secure the in-cab fuse/circuit breaker panel door on 5130B/5230 Excavators. The new magnet is bolted to a new angle bracket. The new magnet and new angle bracket hold the fuse/circuit breaker panel door in the open position during VIMS real time analysis.
Adaptable To: The new 154-6818 Angle and 2N-2258 Rivets are effective with 5130B (4CS146) Excavator and 5230 (7LL84) Excavator and is adaptable to all earlier 5130 (7TJ, 5ZL) Excavators, 5130B (4CS) Excavators and 5230 (7LL) Excavators.
Installation Instructions
1. Drill two 4 mm (.16 in) holes into 7I-5307 Channel (6) (not serviced) as shown in Illustration 1, Illustration 2 and Chart 2.
2. Secure one 154-6818 Angle (1) to 7I-5307 (6) with two 2N-2258 Rivets (2).
3. Secure one 148-5558 Catch Magnet (3) to 154-6818 Angle (1) with two 9X-6259 Screws (4) and two 4B-2041 Nuts (5) as shown in Illustration 3.
Illustration 1.
Typical cab.
Illustration 2.
Detail B 7I-5307 Channel (6)
Illustration 3.
View C-C. Installed 148-5558 Catch Magnet (3), 9X-6258 Screws (4) and 4B-2041 Nuts (5).