- Machine Control and Guidance Products
- COMMAND (S/N: MXY1-UP)
Introduction
This special instruction covers the procedure to install improved software to the 366-7696 Communication Radio Gp of machines equipped with CAT® Command for Underground S/N:MXY1-UP. This supplemental product support literature should be used with the appropriate Service Manual and the appropriate Parts Manual that is available for this standard equipment.
Read the entire Special Instruction. Understand the information before you perform any procedures. Understand the information before you order any parts.
Safety Section
Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.
Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard. Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive.
Ensure that all personnel are safe when using a tool, procedure, work method, or operating technique not recommended by Caterpillar. Ensure that the product will not be damaged or the product made unsafe by the operation, lubrication, maintenance, or the repair procedures that are used.
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin. |
Personal injury or death can result from machine articulation or movement. Machine frames can move and a person can be crushed. Connect the steering frame lock between the front and rear frames before working on the machine. Before operating the machine, place the steering frame lock in the stored position. Failure to place the steering frame lock into the stored position before operating can result in loss of steering. |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
Reference Section
Reference: Operation and Maintenance Manual, SEBU8801, "Command for Underground".
Parts Required
Parts Required | ||
Qty | Part Number | Description |
1 | NDM Diagnostic Software2.20.1 | |
1 | Radio Firmware 5.54.4 |
Tools Required
Tools Required | |||
---|---|---|---|
Tool | Part Number | Part Description | Qty |
A | Power Cable As | 1 | |
B | Lan Ethernet Cable As | 1 |
Prepare to Upgrade Firmware of On-board Radio
Preparation is required to upgrade the firmware to an on-board radio that is installed on a machine, and is not in a Command for Underground area.
- Isolate the machine. Refer to Operation and Maintenance Manual, Machine Isolating for Maintenance.
- Remove the machine from the operations area.
- Move the machine to a hard level surface away from operating machines and away from personnel.
- Engage the parking brake. Place wheel blocks in front of the wheels and behind the wheels.
- Stop the engine.
- Install the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Remove and Install" for the machine.
- Turn the key start switch and the battery disconnect switch to the OFF position. If there is no battery disconnect switch, remove the negative battery cable at the battery.
- Release system pressure. Refer to Disassembly and Assembly, "System Pressure - Release".
- Turn the battery disconnect switch and the key start switch to the ON position.
- Turn the remote autonomous control switch to the ON position.
- Turn the autonomous control enable switch to the AUTO position.
Show/hide table
Illustration 1 g06203386 View of hardware on machine
(1) RJ45 connector
(2) M12 connector
(3) Automation Interface Control Module (AICM) - Install M12 connector (2) of Tooling (A) to service port of AICM (3).
- Install RJ45 connector (1) of Tooling (A) to Ethernet port of service laptop. Refer to Illustration1.
- Power up the service laptop.
- Proceed to "Install Radio Firmware".
Prepare to Upgrade Firmware Using Command for Underground Site Server
The following preparation is required to upgrade the firmware to the local area radio network (LARN) off-board radios.
- Make sure that all machines are out of the operations area.
- Make sure that all off-board radios are in the Command area.
- Power up the operator station and the off-board radio system. Refer to Operation and Maintenance Manual.
- Proceed to "Install Radio Firmware".
Prepare to Upgrade Firmware of Stand-Alone Radio
Preparation is required to upgrade the firmware to a 366-7696 Communication Radio Gp that is not installed on a machine, and is not in a Command for Underground area.
Connect the Radio
- Install M12 connector (3) of Tooling (B) to Ethernet port of radio.
- Install RJ45 connector (1) of Tooling (B) to Ethernet port of service laptop.
- Install M12 connector (2) of Tooling (A) to power supply port of radio.
- Install 4-pin Deutsch connector (4) of Tooling (A) to 24V DC power supply. Refer to Illustration 2.
- Power up the service laptop.
Illustration 2 | g06347473 |
View of hardware (1) RJ45 connector of (2) M12 connector of (3) M12 connector of (4) 4-pin Deutsch connector of |
Assign IP Address
Before installing the software, the radio must be assigned an IP address. The radio may be assigned a dynamic IP address, which requires a DHCP server, or a static IP address. Choose the type of IP address that is required by Command for Underground at your location.
- Assign the correct IP address range to the DHCP server. Refer to user manual for DHCP server.
Show/hide table
Illustration 3 g06347474 (5) "CAT Networking Device Manager" icon - Double-click icon (5) to open "CAT Networking Device Manager" "CAT NDM". If there is no "CAT NDM" software on the laptop, proceed to "To install correct version of CAT NDM". Refer to Illustration 3.
Show/hide table
Illustration 4 g06347476 View of "CAT NDM" screen
(6) "Essential Config." button - Select "Essential Config." (6). Refer to Illustration 4.
Show/hide table
Illustration 5 g06347478 View of "CAT NDM" screen
(7) "Obtain an IP address automatically" check box
(8) "Apply Changes" button
(9) "Close" button
(10) "Status" box - Check the box "Obtain an IP address automatically" (7).
- Select "Apply Changes" (8). When complete, "Status" box (10) will read "Configuration OK".
- Select "Close" (9). Refer to Illustration 5.
- Proceed to "Install Radio Firmware".
- Select icon (5) to open "CAT Networking Device Manager" "CATNDM". If there is no "CATNDM" software on the laptop, proceed to "To install correct version of CAT NDM". Refer to Illustration 6.
Show/hide table
Illustration 7 g06347479 View of "CAT NDM" screen
(11) "Essential Config." button - Select "Essential Config." (11). Refer to Illustration 7.
Show/hide table
Illustration 8 g06347485 View of "CAT NDM" screen
(12) "Obtain an IP address automatically" check box
(13) "IP address" box
(14) "Subnet mask" IP address box - Uncheck the box "Obtain an IP address automatically" (12).
- Change the IP address (13) to the correct value for your site.
- Make sure that the computer and the radio have the same "subnet mask" IP address (14). Refer to Illustration 8.
Show/hide table
Illustration 9 g06347498 View of "CAT NDM" screen
(15) "Apply Changes" button
(16) "Status" box
(17) "Close" button - Select "Apply Changes" (15). When complete, "Status" box (16) will read "Configuration OK".
- Select "Close" (17). Refer to Illustration 9.
- Proceed to "Install Radio Firmware".
Illustration 6 | g06347474 |
(5) "CAT Networking Device Manager" icon |
Install Radio Firmware
Do not upgrade CAT NDM software before upgrading the radio firmware. If CAT NDM is not installed on the service laptop, proceed to "To install correct version of CAT NDM".
Make sure that the power supply is not interrupted during the firmware upgrade. If the power supply is interrupted during firmware upgrade, the radio may be rendered unserviceable.
The most recent software is available at https://dealer.cat.com/en/products/technology/mining-technology-autonomy/command/underground/command-for-underground-release-documentation-and-downloads.html
- Select icon (5) to open "CAT Networking Device Manager" "CAT NDM". Refer to Illustration 10. If there is no "CAT NDM" software on the laptop, proceed to "To install correct version of CAT NDM".
Show/hide table
Illustration 11 g06347491 (18) Advanced Wireless tab.
(19)567-7079 (Firmware 5.54.4) has the "no subnet isolation" configured by default when in the "onboard" role. - On board radio setup.
Show/hide table
Illustration 12 g06348825 - Firmware upgrade CATNDM (20) window.
- Press the box next to upgrade file name; (21) direct the file location where firmware 5.4.4 file is located.
Show/hide table
Illustration 13 g06352073 - Off-board Setup..
- Upgrade file name (22).
- Select the " Upgrade " button (23) to Load correct file.
- Do not power down the radio until the radio finished firm grade upgrade process which takes up to 120 seconds. When the upgrade process is completed the radio should reappear on the NDM.
Show/hide table
Illustration 14 g06348829 - On completion of successful transfer and upgrade continue for radio configuration.
- Ensure Transfer OK (24).
- Ensure Upgrade OK (25).
Show/hide table
Illustration 15 g06348830 - Radio status " ON BOARD / OFF BOARD " (26)
- Once Firmware update is completed change the role from offboard to onboard. (27) (if required)
Show/hide table
Illustration 16 g06348831 Configuration screen for On-Board and Off-Board radio's selection. - Radio configuration settings.
- Changing role from offboard to onboard if required. Use (28) to select the correct role and (29) to apply the change (30) Monitor status box for configuration completion.
- Select the correct preferences for the site applications.
Show/hide table
Illustration 17 g06348833 - Connectivity status Command ping and status of media connection.
- Loss of connectivity following a change from offboard to onboard (31).
- Reboot and Ping status.
Show/hide table
Illustration 18 g06348835 - Reboot "Physically power off onboard radio " (32) (power- off / on) and confirmation of full connectivity.
- Ping onboard radio following reboot.
Show/hide table
Illustration 19 g06348836 - Red C-Key LED on the front of the radio. (33)
- Clear the C-Key by going into the configuration page of the radio unit and selecting "Clear C-Key" in the "Advanced" tab.
Show/hide table
Illustration 20 g06348837 C-Key management tab in Advanced menu. - Select Advanced tab. (34).
- Reboot the device in the "Advanced-C-Key" menu as shown. (35).
Show/hide table
Illustration 21 g06345480 - Rebooting the On-Board radio. (" Please Wait ").
Show/hide table
Illustration 22 g06348841 - Visually confirm that the C-Key LED (36) on the front of the radio unit is (Green). The radio is now ready for deployment.
Illustration 10 | g06347474 |
(1) "CAT Networking Device Manager" icon |
Remove and Uninstall previous version of CATNDM
- In Control panel select Programs (37) to uninstall CATNDM
Show/hide table
Illustration 24 g06348850 - Select Uninstall. (38).
- Select CATNDM. Devices Manager. (39).
Show/hide table
Illustration 25 g06348859 - After uninstalling the CATNDM application, delete all NDM configuration files.
- Go to C:\Users\user name directory and delete all CATNDM files as shown below.
- Delete the files (40)"NDM", (41)"NDMLock" and (42)"ndm.sqlite" if present.
Illustration 23 | g06348844 |
To install correct version of CAT NDM
- To install CATNDM 2.20.1, double-click CATNDMsetup.V2.20.1 .
Show/hide table
Illustration 27 g06348860 - When application runs press Next (43) Using the Networking Devices Manager Setup Wizard.
Show/hide table
Illustration 28 g06348861 - Installing using CATNDM install wizard. (44).
Show/hide table
Illustration 29 g06342037 - " Please wait " while setup installs.
Show/hide table
Illustration 30 g06348862 - On completion of installing select Finish (45) to exit the setup wizard.
Show/hide table
Illustration 31 g06348865 - After installing the CATNDM 2.20.1, the radio should appear CATNDM application (46) Check for correct firmware at (47).
Illustration 26 | g06345491 |
- The default security for the radio units is WEP (48) using a 128bit (26 hex digits) key.
- The radio units (onboard and offboard) can be configured to WPA/WPA2-PSK if required.
Illustration 32 | g06348866 |
Illustration 33 | g06348870 |
WPA/WPA2-PSK (49) Security option now available.
Illustration 34 | g06348871 |
Pre shared Key is the same for all radios, da5ca7da5ca7da5ca7da5ca777 (50).
NOTICE |
---|
If changing wireless security settings ensure that all radios are configured and have the same security settings. A failure to have all settings the same will cause a loss of communication between radio's. |
NOTICE |
---|
In the event of any replacement radio's being fitted ensure that all security settings are set the same, to enable communication between all radio's. |