Required Tools | |||
---|---|---|---|
Tool | Part Number | Description | Qty |
A | 138-7575 | Link Bracket | 1 |
Start By:
- Remove the batteries. Refer to Disassembly and Assembly, "Battery - Remove and Install".
Personal injury can result from hydraulic oil pressure and hot oil. Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system. Make sure all of the work tools have been lowered to the ground, and the oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide"for tools and supplies to collect and contain fluids in Caterpillar machines. Dispose of all fluids according to local regulations. |
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes.
- Remove harness assembly (1) from the clip.
- Disconnect harness assembly (2) from vibratory valve block (3).
Show/hide table
Illustration 2 g02463422 - Remove the bolts and pull vibratory valve block (3) away from the battery box.
Show/hide table
Illustration 3 g02463439 - Remove bolt (4), the plate, and the clamps. Move the cable assemblies out of the way.
- Attach Tooling (A) and a suitable lifting device to battery box (5). Remove bolts (6) and battery box (5).
Show/hide table
Illustration 4 g02463388 - Disconnect harness assembly (9).
- Disconnect hose assemblies (7), (8), (10), and (12) from gear motor assembly (11).
Show/hide table
Illustration 5 g02463389 - Remove bolts (13) and gear motor assembly (11).
Show/hide table
Illustration 6 g02463390 - Loosen set screws (17) and remove blower (18).
- Remove the nuts, the washers, bolts (16), and plate (15) from gear motor assembly (11).
Illustration 1 | g02463420 |
- Install gear motor assembly (11) in the reverse order of removal.
- Adjust blower (18) until a
6 mm (0.23 inch) gap exists between blower (18) and the inlet cone.
- Adjust blower (18) until a
End By:
- Install the batteries. Refer to Disassembly and Assembly, "Battery - Remove and Install".