Personal injury or death can result from a bucket falling. Keep personnel away from the front of the machine when lowering the bucket. |
Two lift load control valves are used. The control valve (if equipped) is used to hold the lift arms in place in case of a hose failure in the lift circuit.
One lift load control valve is located on each lift cylinder.
If there is a loss of hydraulic power, perform the following procedure to lower the lift arms to the ground.
- Turn the engine start switch key to the ON position.
- Slowly tap the loader control lever into the FLOAT position in order to lower the bucket to the ground.
Personal injury or death can result from the implement falling. Keep personnel away from the rear of the machine when lowering the implement. |
Illustration 1 | g01322425 |
If there is a loss of hydraulic power, Use manual release lever (1) for the three-point hitch control valve in order to lower the three-point hitch.
Note: Move the manual release lever slowly.