- Excavator:
- 311C U (S/N: PAD1-UP; CKE1-UP)
- Mobile Hydraulic Power Unit:
- CIPI (S/N: 05A1-UP; 0EM1-UP)
- 312C (S/N: CAE1-UP; BNN1-UP; DBN1-UP; FDS1-UP)
- 312C L (S/N: CBA1-UP; BWH1-UP; CBT1-UP)
- 314C CR (S/N: KJA1-UP; SNY1-UP)
- 314C LCR (S/N: PCA1-UP)
- 315C (S/N: CFB1-UP; AKE1-UP)
- 315C L (S/N: CJC1-UP; ANF1-UP; CFT1-UP)
- 318C (S/N: FAA1-UP; GPA1-UP; BTG1-UP; DAH1-UP; MDY1-UP)
- 319C LN (S/N: KGL1-UP)
- 320C (S/N: MAB1-UP; AMC1-UP; BDC1-UP; DBG1-UP; BCN1-UP; RAW1-UP)
- 320C L (S/N: EGA1-UP; GAA1-UP; GLA1-UP; ANB1-UP; PAB1-UP; BDE1-UP; EAG1-UP; JPL1-UP; SBN1-UP; BER1-UP)
- 320C S (S/N: BBL1-UP; EGL1-UP; BMZ1-UP)
- 320C LN (S/N: BEA1-UP; JTG1-UP; AXK1-UP)
- 320C LU (S/N: CLZ1-UP)
- 320C LRR (S/N: PAC1-UP; GAD1-UP)
- 320C FMST (S/N: BKK1-UP; TBR1-UP)
- 320C FMHW (S/N: BGB1-UP; SAH1-UP)
- 321C LCR (S/N: MCF1-UP; KCR1-UP)
- 322C L (S/N: FED1-UP; BKJ1-UP; HEK1-UP; BGR1-UP; MAR1-UP)
- 322C LN (S/N: BFK1-UP; EMR1-UP)
- 322C FMST (S/N: BPH1-UP; M2H1-UP)
- 322C FMHW (S/N: CAM1-UP; C3R1-UP; LAR1-UP; CBY1-UP)
- 322C FM LGP (S/N: BYL1-UP; SLX1-UP)
- 325C (S/N: JLD1-UP; DTF1-UP; BKW1-UP)
- 325C L (S/N: CRB1-UP; JLC1-UP; BFE1-UP; BMM1-UP)
- 325C MH (S/N: S2C1-UP)
- 325C LN (S/N: CSJ1-UP)
- 325C FMST (S/N: G1L1-UP)
- 325C FMHW (S/N: M2K1-UP; S3M1-UP; Y4P1-UP)
- M325C (S/N: XJA1-UP; PAN1-UP)
- 330C (S/N: JAB1-UP; JCD1-UP)
- 330C L (S/N: CYA1-UP; KDD1-UP; JNK1-UP; MKM1-UP; CAP1-UP; DKY1-UP)
- 330C MH (S/N: D3C1-UP)
- 330C LN (S/N: CGZ1-UP)
- 330C FMST (S/N: B3M1-UP)
- 330C FMHW (S/N: B1K1-UP; B2L1-UP; B4N1-UP)
The new 316-4022 Modular Handle Gp is available for the replacement of the former 187-9975 Modular Handle Gp in the joystick control gp on the machines that are listed. The push switch in the new handle control is improved.
The push switch in the former modular handle gp could fail from an open circuit. The open circuit would prevent the activation of the hydraulic actuators for the attachments. Normal effort would not activate the push switch. Excessive effort was need in order to activate the push switch in the former modular handle gp. The length of the stroke for the activation of the push switch was too long. The new modular handle gp prevents the need for the excessive effort.
Install a new 316-4022 Modular Handle Gp if the former modular handle gp fails to activate the hydraulic actuators for the attachments. Use the information that follows for the replacement procedure.
Procedure for the Replacement of the Modular Handle Gp
Use the information that follows for the installation of the new modular handle gp.
- Remove boot (D) from the right hand and the left hand modular handle gp. Remove cover (C) from the right hand and the left hand console.
Illustration 1 | g01610633 |
Seat And Console |
Illustration 2 | g01610635 |
View A-A From Illustration 1 (C) Upper cover on the console (D) Boot |
Illustration 3 | g01610773 |
View B-B From Illustration 1 (C) Upper cover on the console (D) Boot |
- Disconnect harness (E) and harness (F) from both of the modular handles. Disconnect 6-pin connector (G) in wiring harness (E) from both modular handles. Disconnect the bullet connector with the 320-Red wire and the bullet connector with the 200-Black wire from the wiring harness in the console for the right hand modular handle gp. Disconnect the bullet connector with the 972-Blue wire and the bullet connector with the 235-Black wire from the wiring harness in the console for the left hand modular handle gp.
Illustration 4 | g01621072 |
Left Hand Modular Handle Gp (E) Wiring harness (F) Bullet connectors |
Illustration 5 | g01621075 |
Right Hand Modular Handle Gp (E) Wiring harness (F) Bullet connectors |
Illustration 6 | g01610673 |
Connectors In The Left Hand Console (G) 6-pin connector (H) Bullet connectors |
Illustration 7 | g01610674 |
Connectors In The Right Hand Console (G) 6-pin connector (H) Bullet connectors |
- Remove pin (J). Remove the handle for the joystick.
Illustration 8 | g01610677 |
Typical Modular Handle Gp (J) Pin |
- Install both of the new modular handles. The part number is identical for both of the modular handles. Install pin (J) in both modular handles. Connect the wiring harness and bullet connectors for the new modular handle groups.
- Install cover (C) on the right hand and the left hand console. Install boot (D) on the right hand and the left hand modular handle gp.