AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Caterpillar


Light Bar Scale - Set

Usage:

12H AMZ

Introduction

By default, the Light Bar Scales option is available for all configurations of AccuGrade GPS system. Depending on the operator configuration settings for your system, some of the options, soft keys, or views discussed in this manual may not be accessible.

Operate to an on-grade tolerance threshold appropriate for the design surface. The Light Bar Scales dialogs set the vertical and horizontal tolerances that apply to the LEDs on the light bars. The horizontal and vertical light bars are set independently of each other.

Tolerance Thresholds

A tolerance threshold for vertical light bars is the distance off-grade at which two LEDs will be lit. A tolerance threshold for horizontal light bars is the distance off-line at which two LEDs will be lit.

When the blade is on-grade (on-line) to within half the tolerance threshold, only the center green LED on the appropriate light bar is lit. As the blade moves offgrade (off-line), additional LEDs are lit.

Other LED distances are automatically scaled from the tolerance threshold.

The vertical tolerance threshold also determines the on-grade tolerance. The on-grade tolerance is the vertical range where the blade is considered to be on-grade. When the blade is in the on-grade range, the Cut/Fill text items and the associated direction arrow are green.

When the blade is out of the on-grade range, one of the following things will occur:

  • The Cut text item and the down arrow will be red.

  • The Fill text item and the up arrow will be blue.

Setting the Light Bar Scales

In order to set the tolerance thresholds, complete the following steps:

  1. From the Setup Menu – Configuration dialog, press the Down arrow or the Up arrow until "Light Bar Scales" is highlighted.



    Illustration 1g01120754

  1. Press the OK key. Refer to Illustration 1.

  1. In the Light Bar Scales dialogs, press "Vertical" in order to set the vertical light bar scale. Use any of the following tools to edit the vertical tolerance value:

    • If you work in meters, press "Default Set 0.050" to set your tolerance to the default value of 0.050 m. If you work in US FT or feet, press "Default Set 0.200".

    • Use the arrow keys to enter the off-grade distance at which two vertical LEDs are lit. Enter a value between 0 and 3.810 m. The remaining threshold values are calculated automatically and appear in the dialog.

    • Press "Half Set 0.025" to set your tolerance to half of the current tolerance.

    • Press "Double Set 0.100" to set your tolerance to double the current tolerance.

    This vertical tolerance value is used as the AccuGrade GPS off-grade limit when automatic controls are turned on. If the cut or fill value at either blade tip exceeds this tolerance for more than three seconds, then the blade will be considered to be off-grade.

  1. Press the "Horizontal" soft key in order to set the horizontal light bar scale. Use any of the following tools to change the horizontal tolerance value:

    • If you work in meters, press "Default Set 0.100" in order to set your tolerance to the default value of "0.100 m". If you work in US FT or feet, press "Default Set 0.400".

    • Use the arrow keys to enter the off-line distance at which two horizontal LEDs are lit. Enter a value between "0" and "7.620 m". The remaining threshold values are calculated automatically and shown in the dialog.

    • Press "Half Set 0.050" to set your tolerance to half of the current tolerance.

    • Press "Double Set 0.200" to set your tolerance to double the current tolerance.

  1. Perform one of the following actions:

    • Press the OK key in order to accept the changes and return to the "Setup Menu – Configuration" dialog.

    • Press the "Esc" key in order to cancel any changes and return to the "Setup Menu – Configuration" dialog. You are asked to confirm that you do not want to save any changes.

    After changing the Light Bar Scales dialog, you can change any of the other items in the "Setup Menu – Configuration" dialog before you complete Step 6.

  1. Press the "Esc" key in order to exit the "Setup Menu – Configuration" dialog. The changes take effect immediately.

Caterpillar Information System:

AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) GPS Accuracy Mode - Set
Repair Procedure for Retainer Assemblies on Track Idlers and Rollers {4159, 4180} Repair Procedure for Retainer Assemblies on Track Idlers and Rollers {4159, 4180}
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Diagnostics - View
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Brightness (Display and Light Bar) - Set
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Blade Wear - Set
C9 Engine for Caterpillar Built Machines Fan Drive - Disassemble
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Beeper - Set
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Avoidance Zone - Set
TH220B, TH330B, TH340B, TH350B, TH355B, TH360B, TH460B, TH560B and TH580B Telehandlers MID 039 - CID 1789 - FMI 02
C9 Engine for Caterpillar Built Machines Fan Drive - Remove
735, 740 and 740 EJECTOR Articulated Trucks Engine Supplement Crankshaft Vibration Damper and Pulley - Remove and Install
2005/06/06 Proper Operation of the Variable Frequency Controller on the Soil Compactors {5258}
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Map Recording - Set
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Settings - Restore
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Settings - Save
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Text Items - Set
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Valve Speed - Set
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Vertical Guidance Method - Set
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Vertical Offset Increment - Set
2005/06/27 Improved Engine Oil Coolers are Now Used {1378}
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Common Problems
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Flashing Messages
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Full Screen Messages
AccuGradeTM - Grade Control System (GPS/ATS/Sonic/Cross Slope) Troubleshooting Techniques
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.