- Off-Highway Truck/Tractor
- 784C (S/N: 2PZ1-UP)
- 785C (S/N: 1HW1-UP; APX1-UP; 5AZ264-UP)
- 785D (S/N: DMC1-UP; MSY1-UP)
- 789C (S/N: 2BW303-UP)
- 789D (S/N: SPD1-UP; SHH1-UP)
- 793C (S/N: CBR1-UP; ATY1-UP; 4GZ1-UP)
- 793D (S/N: FDB1-UP)
- 797 (S/N: 5YW1-UP)
- 797B (S/N: JSM1-UP)
- 785C (S/N: 1HW1-UP; APX1-UP; 5AZ264-UP)
Description Of Change: New software is available for certain machines that are listed above. The new software has improvements and enhancements that are listed below:
Improvements and Enhancements
- Corrected fuel level sensor map to display the corresponding fuel percent on Message Center, when the physical fuel tank was full on the 785C.
- Enhanced low air brake pressure level 3 event (ME# 13024) processing to prevent false triggers, during engine cranking on the 785C.
- Addressed Neutral Lockout indicator to display correct status, based on neutral lockout status from transmission ECM on the 789C series Off-Highway Trucks.
Note: Update to the latest transmission file released in SIS Web.
- Enhanced low air brake pressure level 3 event (ME#13024) processing, to prevent false triggers during engine cranking on the 789C series Off-Highway Trucks.
- The new software addresses the Mongolian and Portuguese languages.
- The instrument cluster backlight on certain Off-Highway Trucks.
- The engine overspeed logic on the 793D series Off-Highway Trucks updated with the logic that event code #13228 will trigger when the engine speed is greater than 2025 rpm.
- Corrected trigger conditions for Low Brake/Air Pressure Event (ME#13024) on the 785D, 789D, and 793D series Off-Highway Trucks.
- The MP# for Total Fuel parameter has been changed to 807 instead of 187 on the 785D, 789D, and 793D series Off-Highway Trucks.
- Improvements to the Fuel Tank Level Monitoring on the 797 and 797B series Off-Highway Trucks.
Note: An interim solution existed that had instructed the technician to: Extract pin J1-63 from the ABL2M ECM. Extract pin J1-2 (ABL ground) and apply a Y splice tying J1-63 and J1-2 together. Reinstall the remaining end of the Y splice back into J1-2. If this procedure has been implemented, return the circuit back to the original configuration prior to loading the new software.
Adaptable To: The part number for the new software is listed in Table 1:
Qty | New Part Number | Description | Old Part Number | Application | Language | Sales Model |
---|---|---|---|---|---|---|
1 | Monitor Software Gp | Standard | English/Spanish | 784C | ||
1 | Monitor Software Gp | Standard | English/Spanish | 785C | ||
1 | Monitor Software Gp | Standard | English/Indonesian | |||
1 | Monitor Software Gp | Standard | English/Russian | |||
1 | Monitor Software Gp | Standard | English/French | |||
1 | Monitor Software Gp | Standard | English/Portuguese | |||
1 | Monitor Software Gp | Standard | English/Swedish | |||
1 | Monitor Software Gp | Standard | English/Mongolian | |||
1 | Monitor Software Gp | Standard | English/Spanish | 785D | ||
1 | Monitor Software Gp | N/A | Standard/High Altitude | English/French | ||
1 | Monitor Software Gp | Standard | English/Russian | |||
1 | Monitor Software Gp | Standard | English/Norwegian | |||
1 | Monitor Software Gp | Standard | English/Finland | |||
1 | Monitor Software Gp | n/a | Standard | English/Portuguese | ||
1 | Monitor Software Gp | Standard | English/Spanish | 789C | ||
1 | Monitor Software Gp | Standard | English/Indonesian | |||
1 | Monitor Software Gp | Standard | English/Russian | |||
1 | Monitor Software Gp | Standard | English/French | |||
1 | Monitor Software Gp | Standard | English/Portuguese | |||
1 | Monitor Software Gp | Standard | English/Swedish | |||
1 | Monitor Software Gp | Standard | English/Norwegian | |||
1 | Monitor Software Gp | Standard | English/Turkish | |||
1 | Monitor Software Gp | High Altitude | English/Spanish | |||
1 | Monitor Software Gp | Trans Lock | English/Spanish | |||
1 | Monitor Software Gp | Standard | English/Spanish | 789D | ||
1 | Monitor Software Gp | Standard | English/Russian | |||
1 | Monitor Software Gp | n/a | Standard | English/Portuguese | ||
1 | Monitor Software Gp | Standard | English/Spanish | 793C | ||
1 | Monitor Software Gp | Standard | English/Indonesian | |||
1 | Monitor Software Gp | High Displacement | English/Spanish | |||
1 | Monitor Software Gp | High Displacement | English/Indonesian | |||
1 | Monitor Software Gp | High Displacement | English/Russian | |||
1 | Monitor Software Gp | High Displacement | English/French | |||
1 | Monitor Software Gp | High Displacement | English/Portuguese | |||
1 | Monitor Software Gp | High Displacement | English/Swedish | |||
1 | Monitor Software Gp | Extra Quiet | English/Spanish | |||
1 | Monitor Software Gp | High Displacement Transmission Lock-out | English/Spanish | |||
1 | Monitor Software Gp | Standard/High Altitude | English/Spanish | 793D | ||
1 | Monitor Software Gp | Standard/High Altitude | English/Russian | |||
1 | Monitor Software Gp | Standard/High Altitude | English/Portuguese | |||
1 | Monitor Software Gp | Standard/High Altitude | English/Swedish | |||
1 | Monitor Software Gp | Standard/High Altitude | English/Mongolian | |||
1 | Monitor Software Gp | Standard | English/Spanish | 797 | ||
1 | Monitor Software Gp | Standard | English/Indonesian | |||
1 | Monitor Software Gp | Standard | English/Spanish | 797B | ||
1 | Monitor Software Gp | Standard | English/Indonesian |