Installation Procedure
Personal injury can result from hydraulic oil pressure and hot oil. Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system. Make sure all of the attachments have been lowered, oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Position gear motor (13) onto fan guard (14) and install bolts (15) .
Illustration 1 | g00592341 |
- Install fittings (12) .
- Install adapter (11) onto the shaft of the gear motor.
Illustration 2 | g00769128 |
- Place fan (8) on adapter (11). Install bolts (9). Install bolt (10). Tighten bolt (10) to a torque of 30 ± 7 N·m (22 ± 5 lb ft).
Illustration 3 | g00769100 |
- Position fan assembly (7) and install bolts (6). Tighten bolts (6) to a torque of 30 ± 7 N·m (22 ± 5 lb ft).
Illustration 4 | g00769090 |
- Install hose assemblies (5), (4), and (3) .
Illustration 5 | g00769086 |
- Install tube assemblies (2) and (1) .
Illustration 6 | g00769079 |
- Check the hydraulic oil level. If the hydraulic oil level is low, add hydraulic oil to the hydraulic tank. Refer to Operation and Maintenance Manual, "Hydraulic System Oil Level - Check" for the proper procedure.
- Start the engine and check for leaks.