Removal procedure
Accidental machine starting can cause injury or death to personnel working on the machine. To avoid accidental machine starting, turn the battery disconnect switch to the OFF position and remove the key. If the machine is not equipped with a battery disconnect switch, disconnect the battery cables from the battery and tape the battery clamps. Place a do not operate tag at the battery disconnect switch location to inform personnel that the machine is being worked on. |
- Disconnect the battery cables. Refer to Disassembly and Assembly, "Battery and Battery Cable - Seperate and Connect".
- Remove nut (1) .
Illustration 1 | g01033410 |
- Slide boot (2) away from the positive terminal on electric starting motor (3) .
- Remove nut (4). Disconnect positive cable (5) from electric starting motor (3) .
Illustration 2 | g01033411 |
- Remove nut (9). Disconnect negative cable (10) from electric starting motor (3) .
- Disconnect wire (8) .
- Support electric starting motor (3) .
- Remove nut (6) and clip (7) .
- Remove electric starting motor (3) .
Installation Procedure
Accidental machine starting can cause injury or death to personnel working on the machine. To avoid accidental machine starting, turn the battery disconnect switch to the OFF position and remove the key. If the machine is not equipped with a battery disconnect switch, disconnect the battery cables from the battery and tape the battery clamps. Place a do not operate tag at the battery disconnect switch location to inform personnel that the machine is being worked on. |
- Place electric starting motor (3) in position.
Illustration 3 | g01033411 |
- Install clip (7) and nut (6). Tighten nut (6) to a torque of 50 ± 6 N·m (37 ± 4 lb ft).
- Connect negative cable (10) to electric starting motor (3) and install nut (9). Tighten nut (9) to a torque of 50 ± 6 N·m (37 ± 4 lb ft).
- Connect wire (8) .
- Connect positive cable (5) to electric starting motor (3) and install nut (4) .
- Slide boot (2) over the positive terminal of electric starting motor (3) .
Illustration 4 | g01033410 |
- Install nut (1). Tighten nut (1) to a torque of 50 ± 6 N·m (37 ± 4 lb ft).
- Connect the battery cables. Refer to Disassembly and Assembly, "Battery and Battery Cable - Seperate and Connect".
- Start the engine and check for proper operation of the electric starting motor.