Illustration 1 | g00628823 |
Illustration 2 | g00628825 |
(1) Clearance between new turbine and new converter housing
- Clearance ... 2.39 ± .50 mm (0.094 ± 0.020 inch)
- Permissible wear (maximum) ... 3.58 mm (0.141 inch)
(2) Clearance between new impeller and new converter housing
- Clearance ... 1.55 ± .33 mm (0.061 ± 0.013 inch)
- Permissible wear (maximum) ... 2.33 mm (0.092 inch)
(3) Clearance between new stator and new turbine
- Clearance ... .76 ± .26 mm (0.030 ± 0.010 inch)
- Permissible wear (maximum) ... 1.14 mm (0.045 inch)
(4) Clearance between new stator and new impeller
- Clearance ... .81 ± .26 mm (0.032 ± 0.010 inch)
- Permissible wear (maximum) ... 1.22 mm (0.048 inch)
(5) Clearance between new hub and new bearing in cover assembly ... .113 ± .052 mm (0.0044 ± 0.0020 inch)
(6) Clearance between new hub and new bearing in carrier assembly ... .113 ± .052 mm (0.0044 ± 0.0020 inch)
(7) Clearance between new impeller hub and new bearing carrier ... .35 ± .06 mm (0.014 ± 0.003 inch)
(8) Torque for 20 bolts that fasten the turbine to the hub ... 50 ± 7 N·m (37 ± 5 lb ft)
(9) Torque for 12 bolts that fasten flange assembly to impeller ... 80 ± 10 N·m (60 ± 7 lb ft)
(10) Torque for 12 bolts that fasten gear to flange ... 50 ± 7 N·m (37 ± 5 lb ft)
(11) Torque for 8 bolts that fasten cover assembly to housing ... 30 ± 5 N·m (22 ± 4 lb ft)
(12) Torque for 36 bolts that fasten flange assembly to housing ... 30 ± 5 N·m (22 ± 4 lb ft)