Electronic Modular Control Panel II (EMCP II) For MUI Engines Caterpillar


Alarm Module or Remote Annunciator - Troubleshoot

Usage:

3304 02B



Illustration 1g00481278

System Schematic For Alarm Module (ALM)

All the fault indicators of the remote annunciator flash and/or all the fault indicators of the control panel alarm module flash. The indicators flash once per two seconds (0.5 Hz).

Note: The maximum number of modules (Alarm, Remote Annunciator, or Customer Interface Module), that can be connected to the GSC is three. (There is no limit on the number of Custom Alarm Modules that can be used in an application.) The maximum distance between a module and the GSC is 305 m (1000 ft). If these specifications are not met, the information on the data link can be erratic. Also, the indicators on the alarm module could flash. If the conditions are not in compliance with the specifications, reduce the number of modules and/or shorten the distance to the GSC.

The data link will malfunction under the following conditions with multiple modules:

  • One of the modules is powered down. ("B+" or "B-" is disconnected.)

  • The module that is powered down remains connected to the data link.

Under these conditions, the indicators that are controlled by the data link of the other modules that are powered up will flash at .5 Hz.

  1. Check the data wire.

    1. Turn the ECS to OFF/RESET.

    1. Disconnect the harness connector from the GSC.

    1. Check for an open. Measure the resistance from terminal 2 of the alarm module to contact 35 of the GSC harness connector. The resistance should be 5 ohms or less.

    1. Check for a short. Measure the resistance from contact 35 of the GSC harness connector to the battery (B+) and ground (B-) at the relay module. The resistance should be greater than 5000 ohms.

      Expected Result: For 1.c, the resistance should be 5 ohms or less. For 1.d, the resistance should be greater than 5000 ohms.

      Results:

      • OK - All resistance measurements are correct. Proceed to next step.

      • Not OK - One or more of the resistance measurements are NOT correct. Therefore, the harness wiring with the incorrect resistance is faulty. Troubleshoot the faulty wiring and repair the faulty harness wiring. STOP.

  1. Measure the voltage at the alarm module.

    The ECS remains in the OFF/RESET position.

    1. Reconnect the harness connector to the GSC.

    1. At the alarm module, measure the DC voltage from terminal 2 to terminal 7. The voltage will be changing. The voltage should be between 1 and 10 DCV.

      Note: If you are troubleshooting a remote annunciator, measure the DC voltage from contact 35 to contact 31 of the GSC harness connector. Make the measurement by using the 7X-1710 Multimeter Probe Group. Do not disconnect the harness from the GSC. This voltage measurement should agree with the preceding measurement of 2.b. If the voltages do not agree, the wire is faulty. The wire is faulty from terminal 2 of the remote annunciator to the terminal in the internal panel.

    1. Disconnect all wires from terminal 2 of the alarm module. Again measure the DC voltage from terminal 2 to terminal 7 at the alarm module. The voltage should be 10.5 ± 1.0 DCV.

      Expected Result: For 2.b, the voltage should be between 1 and 10 DCV. For 2.c, the voltage should be 10.5 ± 1.0 DCV.

      Results:

      • OK - Both voltage measurements are correct. Therefore, replace the alarm module. STOP.

      • Not OK - Both voltage measurements are low. Therefore, replace the alarm module.

      • Not OK - The first measurement is low and the second measurement is high. Therefore, replace the GSC. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOP.

Caterpillar Information System:

515 Wheel Skidder and 525 Wheel Skidder Walk-Around Inspection
950G and 962G Wheel Loaders and IT62G Integrated Toolcarrier Machine Systems Main Control Valve and Mounting Plate (Lift and Auxiliary) - Remove
3304B and 3306B Engines for Caterpillar Built Machines Air Compressor - Remove and Install
950G and 962G Wheel Loaders and IT62G Integrated Toolcarrier Machine Systems Main Control Valve and Mounting Plate (Lift and Auxiliary) - Install
69D and 769D Off-Highway Trucks and 771D Quarry Truck Magnetic Switch (Prelubrication Relay) - Remove and Install
3304B and 3306B Engines for Caterpillar Built Machines Water Directors - Remove and Install
Challenger 35, Challenger 45 and Challenger 55 Agricultural Tractors Implement, Steering and Brake Hydraulic Systems Steering Control
69D and 769D Off-Highway Trucks and 771D Quarry Truck Machine Systems Rear Suspension (Cylinder) - Remove
69D and 769D Off-Highway Trucks and 771D Quarry Truck Machine Systems Rear Suspension (Cylinder) - Install
69D and 769D Off-Highway Trucks and 771D Quarry Truck Machine Systems Front Suspension (Cylinder) - Remove
69D and 769D Off-Highway Trucks and 771D Quarry Truck Machine Systems Front Suspension (Cylinder) - Install
69D and 769D Off-Highway Trucks and 771D Quarry Truck Machine Systems Front Suspension (Cylinder) - Disassemble
69D and 769D Off-Highway Trucks and 771D Quarry Truck Unit Injector Hydraulic Pump Drive - Remove
980G Wheel Loader Braking System Parking Brake - Manual Release
D250E Series II and D300E Series II Articulated Trucks Machine Systems Hoist Control Valve - Assemble
980G Wheel Loader Braking System Parking Brake Control Cable - Adjust
24H Motor Grader Power Train Hydraulic Filter (Differential)
Repairing the Nonmetallic Fenders, Machine Hoods, and Tank Covers {1273, 7251, 7252} Repairing the Nonmetallic Fenders, Machine Hoods, and Tank Covers {1273, 7251, 7252}
IT14G Integrated Toolcarrier and 914G Wheel Loader Machine Systems Gear Pump (Implement, Steering and Brakes) - Remove
D250E Series II and D300E Series II Articulated Trucks Machine Systems Pressure Reducing Valve - Remove and Install
Installation of 164-4636 Coolant Recovery Tank {1354} Installation of 164-4636 Coolant Recovery Tank {1354}
950G Wheel Loader, 962G Wheel Loader and IT62G Integrated Toolcarrier Hydraulic System Pilot Valve
D250E Series II, D300E Series II, D350E Series II and D400E Series II Articulated Trucks Power Train Electronic Control System CID 0144 FMI 03 Relay (Backup Alarm) Voltage Above Normal - Test
Electronic Modular Control Panel II (EMCP II) For MUI Engines Zero Display of Voltage or Current - Troubleshoot
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.