Usage:
824G (4SN) Wheel Tractors;
825G (6RN),
826G (7LN) Compactors;
980G (2KR, 9CM, 2SR) Wheel Loaders
Reference: Service Manual, SENR5891-01, Electronic Implement Control System. This module is found in Service Manual SENR1325 and SENR5870.
In the Service Manual, on Page 34, in column two, under "Payload Monitor" Step 1, the word "MODE" should be changed to "SERVICE" and under Step 2, change the word, "SCROLL" to read "NEXT FUNCTION". Delete the next sentence "The sensor duty cycle is shown on the payload display with an extra zero, example: 14% is shown as 140".
On Page 35, column two, after Step 7, the following note should be added: Note: If using the Payload Control System then the values should be between 9175 and 11796. Also on Page 35, column two, after Step 10, the following note should be added: Note: If using the Payload Control System then the values should be less than 58982.