1994/12/26 Caterpillar


New Oil Tube Clamp Assembly Is More Durable and More Resistant to Leakage {1307}

Usage:


D11 (74Z),
D11N (4HK) Track Type Tractors;
776B (6JC),
776C (2TK),
784B 5RK Tractors;
777B (4YC),
777C (4XJ),
785 (8GB),
785B (6HK),
789 (9ZC),
789B (7EK),
793 (3SJ),
793B (1HL) Trucks;
994 (9YF) Wheel Loaders;
5130 (7TJ, 5ZL),
5230 (7LL) Excavators

Description of Change: A new clamp assembly, with centering ring and teflon coated O-ring, provides improved wear resistance. The new clamp assembly reduces vibration of the oil tube because of its increased holding ability over the former retainer. The new clamps also keep the tube centered on the flange. The new teflon coated O-ring is also more durable and leak resistant.

Adaptable To: See the chart for a list of parts required to install one new clamp assembly.

NOTE: The new clamp assembly will not fit in some locations. In these cases, use the former 8N-1992 Retainer, 8N-1991 Ring, and a new 109-2332 O-ring.

Assembly Instructions:


Installing clamp assembly onto oil tube. (1) O-ring. (2) Ring. (3) Clamp. (4) Bolt. (5) Nut. (6) Washer. (7) Bolt. (8) Washer.

1. Install O-ring (1) and ring (2).

2. Assemble two clamps (3) onto tube using bolts (4), washers (6) and nut (5). Do not fully tighten bolts.

3. Install bolts (7) and washers (8) through clamp assembly into the adapter and tighten to 47 N·m (34 lb ft).

NOTE: When installing the new clamps, if the bosses do not line up with the adapter bolts holes, rotate and/or flip the clamps 180 degrees to align the bosses with the bolt holes.

4. Tighten bolts (4) to 47 N·m (34 lb ft).

Caterpillar Information System:

1994/12/26 Information Release Memo PELE0401 Has Information About Remanufactured Hydraulic Piston Pump And Piston Motor Groups {0374,4134,4136,4351,5058,5070,5080,5314,5315,5473}
1994/12/26 New Bearing Housing Used In Turbocharger Group {1056,1052}
1994/12/26 New Engine Oil Pressure Gauge And Sender {7455}
1994/12/19 New Electronic Control Group (Throttle Position Sensor) Has Improved Contact Design {1913}
1994/12/19 New Water And Oil Temperature Regulators Available {1330,1355}
1994/12/19 New Connecting Rod Assembly Has Increased Fatigue Strength {1218}
1994/12/19 Special Instruction SEHS9734-01 Is Available For Retrofitting R-12 Air Conditioning Systems To R-134a Refrigerant {7320,1809}
1994/12/19 Spacer Plate Is Available To Make Installation Of Permanent Hose Couplings Easier {0684,5057}
1994/12/19 New Filter Used For Screed Burner And Washdown Systems {1274,5642}
1994/12/19 Primary Pressure For The Transmission Pressure Control Group Has Been Increased {0374,3150}
1994/12/19 New Screen Assembly Prevents Large Debris From Transferring Into Differential Compartment {4051,3258}
1994/12/19 Small Cracks Around The Holes In The Front Wheels Can Be Repaired By Welding {4201}
1995/01/16 Special Instruction SEHS9429-01 Available for Spherical Bearings for Bulldozers and Rippers{7551,6050,6313}
1995/01/16 Fuel Injection Pump Change{1251}
1995/01/16 R-134a Refrigerant Used For Air Conditioner Charge{1802,1805}
1995/01/16 Boom Lock Cable Tube Is Now Serviceable{5477,5063}
1995/01/16 Wheel Bearing Check And Adjustment Maintenance Interval{4208}
1995/01/16 Maintenance Intervals Are More Uniform{0375,1300,1350,3250,5600,6600}
1995/01/16 New Exhaust Manifold Gasket Available{1059}
1995/01/16 Catalytic Converter And Exhaust Conditioning Products Available{1091}
1995/01/16 New Tube Assemblies Used In Fuel Lines Groups{1274}
1995/01/16 New Oil Pans Have Oil Level Sensor Mounting Hole{1302}
1995/01/16 Fabricated Spacer Will Help Prevent Fan Belt Loss{1357,1359,1405}
1995/01/23 Parts Are Now Serviceable For Roading Lights {1429}