Usage:
All Generator Sets With 447, 448, 449, 450, 592, 593, 594, 595, 596, 597, and 598 Frame Size Generators
Description of Change: The 447, 448, 449, 450, 592, 593, 594, 595, 596, 597, and 598 Frame SR4B Generators with 6 or 12 lead connections should not be reconnected to a delta configuration. When these types of generators are connected in the delta configuration, the circulating current within the delta will cause additional heat in the generator stator.
Adaptable To: Wiring control films for 4/6 and 10/12 lead connections provided with generators of the frame sizes listed above, have been changed. The 139-9026 Control Panel Film replaces the former 7E-5940 Film on the generators which have 4 or 6 leads. The 139-9025 Control Panel Film replaces the former 4W-9449 Film on the generators which have 10 or 12 leads.