3512E HD Petroleum Engine Caterpillar


General Hazard Information

Usage:

SPF743 MLX



Illustration 1g03838041

Attach a "Do Not Operate" warning tag to the start switch or controls before the engine is serviced or repaired. These warning tags (Special Instruction, SEHS7332) are available from your Cat dealer. Attach the warning tags to the engine and to each operator control station. When appropriate, disconnect the starting controls.

Do not allow unauthorized personnel on the engine, or around the engine when the engine is being serviced.

Cautiously remove the following parts. To help prevent spraying or splashing of pressurized fluids, hold a rag over the part that is being removed.

  • Filler caps

  • Grease fittings

  • Pressure taps

  • Breathers

  • Drain plugs

Use caution when cover plates are removed. Gradually loosen, but do not remove the last two bolts or nuts that are located at opposite ends of the cover plate or the device. Before removing the last two bolts or nuts, pry the cover loose in order to relieve any spring pressure or other pressure.




Illustration 2g00702020

  • Wear a hard hat, protective glasses, and other protective equipment, as required.

  • When work is performed around an engine that is operating, wear protective devices for ears in order to help prevent damage to hearing.

  • Do not wear loose clothing or jewelry that can snag on controls or on other parts of the engine.

  • Ensure that all protective guards and all covers are secured in place on the engine.

  • Never put maintenance fluids into glass containers. Glass containers can break.

  • Use all cleaning solutions with care.

  • Report all necessary repairs.

Unless other instructions are provided, perform the maintenance under the following conditions:

  • The engine is stopped. Ensure that the engine cannot be started.

  • The protective locks or the controls are in the applied position.

  • Disconnect the batteries when maintenance is performed or when the electrical system is serviced. Disconnect the battery ground leads. Tape the leads in order to help prevent sparks.

  • When starting a new engine, make provisions to stop the engine if an overspeed occurs. If an engine has not been started since service has been performed, make provisions to stop the engine if an overspeed occurs. Shutting down the engine may be accomplished by shutting off the fuel supply and/or the air supply to the engine.

  • Do not attempt any repairs that are not understood. Use the proper tools. Replace any equipment that is damaged or repair the equipment.

  • Start the engine with the operator controls. Never short across the starting motor terminals or the batteries. This method of starting the engine could bypass the engine neutral start system and/or the electrical system could be damaged.

Pressurized Air and Water

Pressurized air and/or water can cause debris and/or hot water to be blown out which could result in personal injury.

The maximum air pressure for cleaning purposes must be reduced to 205 kPa (30 psi) when the air nozzle is deadheaded and used with effective chip guarding (if applicable) and personal protective equipment. The maximum water pressure for cleaning purposes must be below 275 kPa (40 psi).

When pressurized air and/or pressurized water is used for cleaning, wear protective clothing, protective shoes, and eye protection. Eye protection includes goggles or a protective face shield. Always wear eye protection for cleaning the cooling system.

Avoid direct spraying of water on electrical connectors, connections, and components. When using air for cleaning, allow the machine to cool to reduce the possibility of fine debris igniting when redeposited on hot surfaces.

Operation in a Blast Site for Product Link Radios (IF Equipped)

------ WARNING! ------

This equipment is equipped with a Cat® Product Link communication device. When electric detonators are being used for blasting operations, radio frequency devices can cause interference with electric detonators for blasting operations which can result in serious injury or death. The Product Link communication device should be deactivated within the distance mandated under all applicable national or local regulatory requirements. In the absence of any regulatory requirements Caterpillar recommends the end user perform their own risk assessment to determine safe operating distance.

----------------------

For additional information concerning Product Link, refer to the Operation and Maintenance Manual, SEBU8832.

Fluid Penetration




Illustration 3g00687600

Always use a board or cardboard when you check for a leak. Leaking fluid that is under pressure can penetrate body tissue. Fluid penetration can cause serious injury and possible death. A pin hole leak can cause severe injury. If fluid is injected into your skin, you must get treatment immediately. Seek treatment from a doctor that is familiar with this type of injury.

Containing Fluid Spillage


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "Cat Dealer Service Tool Catalog" or refer to Special Publication, PECJ0003, "Cat Shop Supplies and Tools Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.

Dispose of all fluids according to local regulations and mandates.


Static Electricity Hazard when Fueling with Ultra-low Sulfur Diesel Fuel

The removal of sulfur and other compounds in ultra-low sulfur diesel fuel (ULSD fuel) decreases the conductivity of ULSD and increases the ability of ULSD to store static charge. Refineries may have treated the fuel with a static dissipating additive. Many factors can reduce the effectiveness of the additive over time. Static charges can build up in ULSD fuel while the fuel is flowing through fuel delivery systems. Static electricity discharge when combustible vapors are present could result in a fire or explosion. Ensure that the entire system used to refuel your machine (fuel supply tank, transfer pump, transfer hose, nozzle, and others) is properly grounded and bonded. Consult with your fuel or fuel system supplier to ensure that the delivery system complies with fueling standards for proper grounding and bonding.

------ WARNING! ------

Avoid static electricity risk when fueling. Ultra-low sulfur diesel fuel (ULSD fuel) poses a greater static ignition hazard than earlier diesel formulations with a higher sulfur contents. Avoid death or serious injury from fire or explosion. Consult with your fuel or fuel system supplier to ensure the delivery system is in compliance with fueling standards for proper grounding and bonding practices.

----------------------

Lines, Tubes, and Hoses

Do not bend or strike high-pressure lines. Do not install lines, tubes, or hoses that are damaged.

Repair any fuel lines, oil lines, tubes, or hoses that are loose or damaged. Leaks can cause fires.

Inspect all lines, tubes, and hoses carefully. Do not use bare hands to check for leaks. Always use a board or cardboard for checking engine components for leaks. Tighten all connections to the recommended torque.

Check for the following conditions:

  • End fittings that are damaged or leaking

  • Outer covering that is chafed or cut

  • Wire that is exposed in reinforced hose

  • Outer covering that is ballooning locally

  • Flexible part of the hose that is kinked or crushed

  • Armoring that is embedded in the outer covering

Ensure that all of the clamps, the guards, and the heat shields are installed correctly. Correct installation of these components will help to prevent these effects: vibration, rubbing against other parts and excessive heat during operation.

Inhalation




Illustration 4g02159053

Exhaust

Use caution. Exhaust fumes can be hazardous to your health. If you operate the equipment in an enclosed area, adequate ventilation is necessary.

Asbestos Information

Cat equipment and replacement parts that are shipped from Caterpillar are asbestos free. Caterpillar recommends the use of only genuine Cat replacement parts. Use the following guidelines when you handle any replacement parts that contain asbestos or when you handle asbestos debris.

Use caution. Avoid inhaling dust that might be generated when you handle components that contain asbestos fibers. Inhaling this dust can be hazardous to your health. The components that may contain asbestos fibers are brake pads, brake bands, lining material, clutch plates, and some gaskets. The asbestos that is used in these components is bound in a resin or sealed in some way. Normal handling is not hazardous unless airborne dust that contains asbestos is generated.

If dust that may contain asbestos is present, there are several guidelines that should be followed:

  • Never use compressed air for cleaning.

  • Avoid brushing materials that contain asbestos.

  • Avoid grinding materials that contain asbestos.

  • Use a wet method in order to clean up asbestos materials.

  • A vacuum cleaner that is equipped with a high efficiency particulate air filter (HEPA) can also be used.

  • Use exhaust ventilation on permanent machining jobs.

  • Wear an approved respirator if there is no other way to control the dust.

  • Comply with applicable rules and regulations for the work place. In the United States, use Occupational Safety and Health Administration (OSHA) requirements. These OSHA requirements can be found in "29 CFR 1910.1001".

  • Obey environmental regulations for the disposal of asbestos.

  • Stay away from areas that might have asbestos particles in the air.

Softwrap

Keep the engine room ventilation operating at full capacity. Wear a particulate respirator that has been approved by the National Institute of Occupational Safety and Health (NIOSH). Wear appropriate protective clothing in order to minimize direct contact. Use good hygiene practices and wash hands thoroughly after handling Softwrap material. Do not smoke until washing hands thoroughly after handling Softwrap material. Clean up debris with a vacuum or by wet sweeping. Do not use pressurized air to clean up debris.

ReferenceThe applicable material safety data sheets can be found at the following web site by searching using part number or the name:

http://dsf2ws.cat.com/msds/servlet/
cat.cis.ecs.msdsSearch.controller.
UserIdentificationDisplayServlet

Dispose of Waste Properly




Illustration 5g00706404

Improperly disposing of waste can threaten the environment. Potentially harmful fluids should be disposed of according to local regulations.

Always use leakproof containers when you drain fluids. Do not pour waste onto the ground, down a drain, or into any source of water.

Caterpillar Information System:

2015/07/10 An Improved Assembly of the Camshaft Cover Is Now Used on Certain C7 Commercial Engines {1201}
HPU300 Hydraulic Power Pack Safety Messages
C8.7 Marine Engine Fuel Manifold (Rail) - Remove and Install
Bench Test Procedure for Hydraulic Piston Pumps {0784, 5050, 5070} Bench Test Procedure for Hydraulic Piston Pumps {0784, 5050, 5070}
120 and 120 AWD Motor Grader Oil Filter (Implement Controls) - Replace
120 and 120 AWD Motor Grader Hydraulic System Oil Sample - Obtain
3512C Generator Set Engine Camshaft - Install
120 and 120 AWD Motor Grader Maintenance Interval Schedule
G3606 and G3608 Engines Vibration Damper - Install
G3600 A4 Engines Reference Information
C13 Generator Set Refill Capacities
C13 Generator Set Product Description
G3606 and G3608 Engines Crankshaft Rear Seal - Remove and Install
3512C Generator Set Engine Radiator Group - Remove and Install
G3306B Generator Set Maintenance Interval Schedule - Turbocharged
3516C and C175-16 Engines Selective Catalytic Reduction Cat ET Service Features
Cat® Command For Hauling MID 039 - CID 3710 - FMI 02
Cat® Command For Hauling MID 039 - CID 3710 - FMI 19
C8.7 Marine Engine Engine Oil Pan - Remove and Install
3512C Generator Set Engine Radiator Core - Remove and Install
120 and 120 AWD Motor Grader Capacities (Refill)
120 and 120 AWD Motor Grader Lubricant Viscosities - Fluids Recommendations
120 and 120 AWD Motor Grader Brake Accumulator - Check
New Fuel Lines and Mounting Hardware Installation On Certain 3500 Engines{1252, 1274} New Fuel Lines and Mounting Hardware Installation On Certain 3500 Engines{1252, 1274}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.