C13 Industrial Engine Caterpillar


Engine Has Early Wear

Usage:

C13 JR9

Probable Causes

  • Incorrect maintenance intervals and/or incorrect oil

  • Contaminated engine oil

  • Low oil pressure

  • Leaks in the air system

  • Inspect the fuel filters for contamination.

Recommended Actions

Note: The procedures have been listed in order of probability. Complete the procedures in order.

Table 1
Troubleshooting Test Steps  Values  Results 

1. Incorrect Maintenance Intervals and/or Incorrect Oil

A. Use engine oil that is recommended and change the engine oil at the interval that is recommended by the engines Operation and Maintenance Manual.
 

Maintenance intervals
 

Result: The engine oil was changed at the interval that is recommended by the engines Operation and Maintenance Manual.

Proceed to Test Step 2.

Result: The engine oil was not changed at the interval that is recommended by the engines Operation and Maintenance Manual.

Use at least the minimum grade of Cat oil.

Change the engine oil at the interval that is recommended. Repair or replace any damaged parts.
 

2. Contaminated Engine Oil

A. Obtain an S-O-S oil analysis. The analysis will contribute to a better understanding of oil contamination.

B. Check the oil filter bypass valve.

If the oil filter bypass valve is open, the oil will not be filtered. Check the oil filter bypass valve for a weak spring or for a broken spring. If the spring is broken, replace the spring. Verify that the oil bypass valve is operating correctly. Refer to the Disassembly and Assembly manual.

Refer to the Caterpillar guidelines for "Reusability and Salvage/Repair" for determining if the replacement of parts is necessary in order to perform a quality repair.
 

Contamination
 

Result: The oil is contaminated.

Determine the reason for any contamination of the engine oil and make the necessary repairs. Drain the crankcase and refill the crankcase with clean engine oil. Install new engine oil filters. Refer to the engines Operation and Maintenance Manual.

Result: The oil is not contaminated.

Proceed to Test Step 3.
 

3. Low Oil Pressure

A. Engine oil that is contaminated with another liquid can cause low engine oil pressure. High engine oil level can be an indication of contamination. Obtain an analysis of the engine oil.

B. The inlet screen of the suction tube for the engine oil pump can have a restriction. This restriction will cause cavitation and a loss of engine oil pressure. Check the inlet screen on the suction tube and remove any material that may be restricting engine oil flow.

When some components of the engine show wear in a short time, the cause can be a restriction in a passage for engine oil. An indicator for the engine oil pressure may indicate sufficient pressure, but a component is worn due to a lack of lubrication. In such a case, look at the passage for the engine oil supply to the component. Refer to Systems Operation/Testing and Adjusting, "Lubrication System" for additional information.
 

Restriction
 

Result: The inlet tube has a restriction.

Clear the obstruction. Verify the repair.

Result: The inlet tube does not have a restriction.

Proceed to Test Step 4.
 

4. Leaks in Air System

A. A leak in the air intake system may allow unfiltered air into the engine. Inspect the air intake system for streaks which may indicate a leakage of unfiltered air. Inspect all of the gaskets and the connections.
 

Air leak
 

Result: There are no air leaks.

Proceed to Test Step 5.

Result: There are air leaks.

Repair any leaks.
 

5. Inspect the Fuel Filters for Contamination

A. Remove the fuel filters. Inspect the fuel filters for contamination. Contaminants in the fuel such as hydrogen sulfide and sulfur can lead to the formation of acids in the crankcase. Obtain a fuel analysis.
 

Fuel filters
 

Result: The fuel has contamination.

Determine the cause of any contamination and make the necessary repairs.

Install new fuel filters. Refer to the Operation and Maintenance Manual.
 

Complete the procedure in the order in which the steps are listed.

Caterpillar Information System:

C13 Industrial Engine Engine Does Not Crank
G3520H Generator Set Engine Transfer Gearbox - Install
C175-16 Locomotive Engine Clean Emissions Module Has High Oxygen Level
3512E Tier 4 Final Engines for Land Electric Drilling Electrical Power Supply - Test
C13 Industrial Engine Engine Has Mechanical Noise (Knock)
C13 Industrial Engine Engine Cranks but Does Not Start
G3520H Generator Set Engine Transfer Gearbox - Remove
2014/10/31 New Water Lines Are Used On Certain C32 Marine Engines {1052, 1380}
2014/10/31 New Engine Software Is Used on Certain C32 Engines {1902, 1920}
2014/10/23 New Delivery Method for Engine Monitoring System III Software Is Used On Certain 3512C Petroleum Engines {1901, 1920}
2014/10/31 Coolant System Venting Recommendations For Certain G3600 Engines {1350, 1380}
PMG3516 Power Module Maintenance Interval Schedule - Prime Power
C13 Industrial Engine Engine Misfires, Runs Rough or Is Unstable
C13 Industrial Engine Engine Overcrank Occurrence
C13 Industrial Engine Engine Overspeeds
C13 Industrial Engine Engine Shutdown While Idling
C280 Marine Engines Exhaust Differential Temperature Is High
G3520H Generator Set Engine Gear Group (Rear) - Remove and Install
C13 Industrial Engine Engine Stalls at Low RPM
794 AC Off-Highway Truck Engine Supplement Turbocharger - Remove and Install
C13 Industrial Engine Engine Top Speed Is Not Obtained
C13 Industrial Engine Engine Vibration Is Excessive
C13 Industrial Engine Exhaust Has Excessive Black Smoke
Cat® Command For Hauling Turn Signal, Horn, Low Beam Headlight Do Not Activate in Autonomous Mode
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.