Illustration 1 | g03317973 |
Typical example of the fumes disposal filter (1) Crankcase breather (2) Fumes disposal filter base and fumes disposal filter (3) Air cleaner |
The fumes disposal filter requires the replacement of the fumes disposal filter. The service interval of the fumes disposal filter will be affected by the following items:
- Engine load
- Soot concentration
- Condition of the engine
The fumes disposal filter is equipped with a service indicator. If the fumes disposal filter becomes plugged prior to the normal service interval, increased restriction of the filter will cause the vacuum to become positive. When the pressure continues to rise, the service indicator will show through the cap. The service indicator indicates the need for the fumes disposal filter to be changed. Reset the service indicator by using the following procedure:
Resetting the Service Indicator
- Remove the plastic cover (4) .
Illustration 2 | g03317975 |
- Push down on the service indicator (5) .
- Replace the cover (4) .
- Replace the fumes disposal filter by using the following procedure:
Replacing the Fumes Disposal Filter
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin. |
Note: When possible, perform the maintenance while the engine is off.
- Release the latches (7) that hold the canister to the filter base assembly (6) .
Illustration 3 | g03317977 |
- Lower the canister (8) in order to expose the element. There may be oil in the bottom of the canister. Avoid spilling the oil.
Note: The canister (8) may be difficult to remove while the engine is operating. The canister has negative air pressure while the engine is operating which creates a vacuum.
- Remove the filter element by pulling down. Dispose of the used element properly.
- Remove the O-ring assembly on the top end cap of the used element.
- Replace the O-ring seal on the bottom of the filter base assembly.
- Install the new O-ring on the top end cap of the element. Install the element into the correct place.
- Replace the canister (8) and align the canister with the boss on the filter base assembly (6) .
- Clamp the latches (7) in the closed position.