Alternator Problem - Charging Problem and/or Noisy Operation
- Alternator
- Charging Circuit
Note: The procedures have been listed in order of probability. Complete the procedures in order.
Show/hide table
Troubleshooting Test Steps | Values | Results |
---|---|---|
1. Condition of the Alternator Drive Belts A. Inspect the condition of the alternator drive belts. B. Check the belt tension. If the engine is equipped with an automatic belt tensioner, check the automatic belt tensioner. Excessive belt tension can result in damage to the alternator. |
Drive belt |
Result: The alternator drive belts are in good condition and the belt tension is correct. Proceed to Test Step 2. Result: The alternator drive belts are not in good condition or the belt tension is incorrect. Repair:If the alternator drive belts are worn or damaged, replace the belts. Refer to Disassembly and Assembly for the correct procedure. If necessary, replace the automatic belt tensioner. Refer to Disassembly and Assembly for the correct procedure. Verify that the repair eliminated the problem. |
2. Condition of the Alternator Drive Pulley A. Check the condition of the alternator drive pulley. Look for deep grooves that have been worn into the pulley by the belt. Check that the nut for the pulley has not become loose. |
Alternator Drive Pulley |
Result: There is excessive wear on the alternator drive pulley. Repair: Replace the pulley. Result: The alternator drive pulley nut was loose. Repair: Tighten the nut. Verify that the repair eliminated the problem. Result: There is not excessive wear on the alternator drive pulley. Proceed to Test Step 3. |
3. Wear of the Alternator Bearings A. Check the alternator bearings for signs of wear. |
Alternator bearings |
Result: The alternator bearings are OK. Proceed to Test Step 4. Result: The alternator bearings are not OK. Repair: Repair the alternator or replace the alternator, as needed. Refer to Disassembly and Assembly for the correct procedure. Verify that the repair eliminated the problem. |
4. Operation of the Alternator or Regulator A. Verify that the alternator or the regulator is operating correctly. Refer to Special Instruction, REHS0354, "Charging System Troubleshooting" for the proper testing procedures. |
Regulator and alternator |
Result: The regulator and alternator are operating properly. Proceed to Test Step 5. Result: The regulator and alternator are not operating properly. Repair: Repair the alternator and regulator or replace the alternator and regulator, as needed. Refer to Disassembly and Assembly for the correct procedure. Verify that the repair eliminated the problem. |
5. Inspection of the Charging Circuit A. Inspect the battery cables, wiring, and connections in the charging circuit. |
Charging circuit |
Result: The charging circuit is not working properly. Clean all connections and tighten all connections. Replace any faulty parts. Verify that the repair eliminated the problem. |
Complete the procedure in the order in which the steps are listed.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Caterpillar Information System:
C18 Generator Sets Voltage Regulators - R450 Automatic Voltage Regulator (AVR)
3516C Generator Sets Filter Screen (DEF) - Clean/Replace
C18 Generator Sets Engine Air Cleaner Element (Dual Element) - Inspect/Clean/Replace
3516C Generator Sets Filter Screen (Air) - Clean/Replace
2012/03/08 A New Oil Supply Dowel and Dowel Driver Are Used for C175 Cylinder Blocks {1201}
303.5E2, 304E2, 305.5E2 and 305E2 Mini Hydraulic Excavators Belt - Inspect/Adjust/Replace
2011/12/01 Auto Clearing of Diagnostics and Events from Electronic Control Module (ECM) {1901, 1920, 7610, 7620}
C13 Engine for Combat and Tactical Vehicles Water Temperature Regulator Housing
2012/01/12 A New Water Temperature Regulator for the Separate Circuit Is Available for Certain 3500B Locomotive Engines {1355, 1393}
3516C Generator Set Engines Engine Air Cleaner Service Indicator
374F Excavator Machine System Hydraulic Pedal Control (Travel)
320D2 Forest Machine Machine System Specifications Hydraulic Oil Cooler Lines Group
C13, C15, and C18 Tier 4 Final Engines DEF Module Does Not Respond
325D and 329D Excavators Machine System Specifications Travel Motor and Mounting
C175-16 Locomotive Engine Water Temperature Control Valve - Disassemble
2012/03/08 New Turbocharger Oil Lines Are Used on C175-16 Generator Set Engines {1052, 1307}
2012/02/10 A New Bracket Should Be Used When Replacing the Combustion Air Tube on Certain C13 Truck Engines {108N}
3512B and 3512C Petroleum Generator Set Engines Engine Monitoring System
C13 and C15 On-Highway Engines Grounding Stud - Inspect/Clean/Tighten
C13 and C15 On-Highway Engines Refill Capacities
C13, C15, and C18 Tier 4 Interim Engines Cat ET Service Error Identifiers
C18 Generator Sets Circuit Breakers - Reset
An Aid To Reading Multimeter Scales{0785} An Aid To Reading Multimeter Scales{0785}
C175-16 Locomotive Engine Water Temperature Control Valve - Assemble