C32 Marine and Auxiliary Marine Engines Caterpillar


Electric Starting Motor

Usage:

C32 RND



Illustration 1g02563138

Table 1
Specification for 350-1614 Electric Starting Motor Gp    
Item     Qty     Part     Specification Description    
B     -     -     Clearance between the pinion and the housing is
9.1 mm (0.36 inch).    
1     1     -     Torque nut to
8.75 ± 1.05 N·m (77.44 ± 9.29 lb in).    
2     2     -     Torque stud to
2.25 ± 0.25 N·m (19.91 ± 2.21 lb in).    
3     5     6V-8188 Nut     Torque to
30.5 ± 3.5 N·m (269.9 ± 31.0 lb in).    
4     1     4B-2049 Nut     Torque to
2.6 ± 0.8 N·m (23.0 ± 7.1 lb in).    
5     1     4B-2049 Nut     The switch terminal must be insulated with heat shrinkable tubing. Do not use molded terminals.
Torque to
2.6 ± 0.8 N·m (23.0 ± 7.1 lb in).    
6     1     6V-8188 Nut     A maximum of three cable terminals or wire terminals may be used with the battery terminal nut. A maximum of two of the cable terminals may be equal to or greater than 0 AWG.
Torque to
30.5 ± 3.5 N·m (269.9 ± 31.0 lb in).    
-     -     -     Pull-in current at 20 V and
25 °C (77 °F) is 49.3 ± 3.3 Amp.    
Hold-in current at 20 V and
25 °C (77 °F) is 6.8 Amp max.
-     -     -     When the electric starting motor is viewed from the pinion end, the motor rotates in the clockwise direction.    
-     -     -     No load conditions at
25 °C (77 °F):    
Speed is 6612.0 ± 1887.5 rpm.
Current draw is 100 ± 30 Amp.
Voltage is 23 VDC.