Reference: Refer to Testing and Adjusting, "Work Tool Parameter - Program" for additional programming instructions and parameter descriptions.
Pump Flow Control Mode (Parameter #6)
Set the pump to supply oil flow to the work tool using the following parameter settings for the work tool.
Note: "Pump Flow Control Mode" is only available on the 336 through 320 size machines. Drive pump flow is only available for the work tool on the 349 and 311 through 319 size machines for this system.
Pump #1 - Drive Pump
Pump #2 - Idler Pump
Combined Flow - Both Pumps
- Select Pump #1 or Pump #2.
- "ATT Valve #1" (Parameter #27 through #36) are now available for setting.
- "ATT Valve #2" (Parameter #37 through #45) are set by parameters used for "ATT Valve #1" for one pump setting.
- Pump #1 is recommended when multiple operation of work tool along with swing or stick function are frequently used.
- Pump #2 is recommended when multiple operation of work tool along with bucket or boom function are frequently used.
- Select Combined Flow.
- (Parameter #27 through #45) are now available for setting.
Pump Flow to the Work Tool (Single Operation)
One Pump Flow using the Drive or Idler Pump
Note: Drive pump flow is only available for the work tool on the 349 and 311 through 319 size machines for this system.
- Set the appropriate flow for the work tool to be installed by using the following parameter settings.
"Atch #X Flow Setting" (Parameter # 27) - XXX [L/min]
Show/hide tableTable 1 Maximum Flow Setting for One Pump Flow 349E / 349F 385 L/min (101.7 US gal/min) 336E / 336F 289 L/min (76.3 US gal/min) 329E / 329F / 330F 247 L/min (65.3 US gal/min) 326F 231 L/min (61.0 US gal/min) 324E 231 L/min (61.0 US gal/min) 323E / 320E / 320E N / 323 E N / 320E RR 214 L/min (56.5 US gal/min) 320F / 323F N 211 L/min (55.7 US gpm) 323F 209 L/min (55.2 US gpm) 318E / 316E / 318F / 316F 150 L/min (39.6 US gal/min) 314E CR / 314F / 315F 128 L/min (33.8 US gal/min) 312E / 312F / 313F 128 L/min (33.8 US gal/min) - Work tool open and close speed can be decreased by lowering the following parameter value.
- Spool shift pressure adjustment to extend the attachment control valve.
"Atch #X Max Ext Press" (Parameter #30 and #40) - XXXX [kPa]
- Spool shift pressure adjustment to retract the attachment control valve for two-way flow only.
"Atch #X Max Ret Press" (Parameter #31 and #41) - XXXX [kPa]
Note: For reference, this parameter is set within the range of 800 kPa to 2000 kPa.
- Spool shift pressure adjustment to extend the attachment control valve.
Note: Two pump flow is only programmable for the 336 through 320 size machines for this tool system.
- Set the appropriate flow for the work tool to be installed by using the following parameter settings.
"Atch #1 Flow Setting" (Parameter # 27) - XXX [L/min]
Show/hide tableTable 2 Maximum Flow Setting for Two Pump Flow 349E / 349F 770 L/min (203.4 US gal/min) 336E / 336F 578 L/min (152.7 US gal/min) 329E / 329F / 330F 494 L/min (130.5 US gal/min) 326F 462 L/min (122.0 US gal/min) 324E 462 L/min (122.0 US gal/min) 323E / 320E / 320E N / 323 E N / 320E RR 428 L/min (113.1 US gal/min) 320F / 323F N 422 L/min (111.5 US gpm) 323F 418 L/min (110.4 US gpm) - Work tool open and close speed can be decreased by lowering the following parameter value.
- Spool shift pressure adjustment to extend the attachment control valves.
"Atch #1 Max Ext Press" (Parameter #30) - XXXX [kPa]
"Atch #2 Max Ext Press" (Parameter #40) - XXXX [kPa]
- Spool shift pressure adjustment to retract the attachment control valves for two-way flow only.
"Atch #1 Max Ret Press" (Parameter #31) - XXXX [kPa]
"Atch #2 Max Ret Press" (Parameter #41) - XXXX [kPa]
Note: For reference, this parameter is set within the range of 800 kPa to 2000 kPa. A parameter setting for spool shift pressure of 0 kPa is not made for flow from two pumps.
- Spool shift pressure adjustment to extend the attachment control valves.