349E, 349F and 352F Excavators and 349E MHPU Mobile Hydraulic Power Unit Tool Control System Caterpillar


One-Way/One or Two Pump - Electric Control: Parameter Setting

Usage:

352F-VG A9J
These procedures cover specific work tool parameter settings that are commonly used in detail.

Reference: Refer to Testing and Adjusting, "Work Tool Parameter - Program" for additional programming instructions and parameter descriptions.

Supply Pump for the Work Tool

Pump Flow Control Mode (Parameter #6)

Set the pump to supply oil flow to the work tool using the following parameter settings for the work tool.

Pump #1 - Drive Pump

Pump #2 - Idler Pump

Combined Flow - Both Pumps

  1. Select Pump #1 or Pump #2.

    1. "ATT Valve #1" (Parameter #27 through #36) are now available for setting.

    2. "ATT Valve #2" (Parameter #37 through #45) are set by parameters used for "ATT Valve #1" for one pump setting.

      • Pump #1 is recommended when multiple operation of work tool along with swing or stick function are frequently used.

      • Pump #2 is recommended when multiple operation of work tool along with bucket or boom function are frequently used.

  2. Select Combined Flow.

    1. (Parameter #27 through #45) are now available for setting.

Pump Flow to the Work Tool (Single Operation)

One Pump Flow using Drive or Idler Pump

  1. Set the appropriate flow for the work tool to be installed by using the following parameter settings.

    "Atch #X Flow Setting" (Parameter # 27) - XXX [L/min]

    Table 1
    Maximum Flow Setting for One Pump Flow 
    349E / 349F  385 L/min (101.7 US gal/min) 
    336E / 336F  289 L/min (76.3 US gal/min) 
    329E / 329F / 330F  247 L/min (65.3 US gal/min) 
    326F  231 L/min (61.0 US gal/min) 
    324E  231 L/min (61.0 US gal/min) 
    323E / 320E / 320E N / 323 E N / 320E RR  214 L/min (56.5 US gal/min) 
    320F / 323F N  211 L/min (55.7 US gpm) 
    323F  209 L/min (55.2 US gpm) 
    318E / 316E / 318F / 316F  150 L/min (39.6 US gal/min) 
    314E CR / 314F / 315F  128 L/min (33.8 US gal/min) 
    312E / 312F / 313F  128 L/min (33.8 US gal/min) 

  2. Work tool open and close speed can be decreased by lowering the following parameter value.

    1. Spool shift pressure adjustment to extend the attachment control valve.

      "Atch #X Max Ext Press" (Parameter #30 and #40) - XXXX [kPa]

      Note: For reference, this parameter is set within the range of 800 kPa to 2000 kPa.

Two Pump Flow

  1. Set the appropriate flow for the work tool to be installed by using the following parameter settings.

    "Atch #1 Flow Setting" (Parameter # 27) - XXX [L/min]

    Table 2
    Maximum Flow Setting for Two Pump Flow 
    349E / 349F  770 L/min (203.4 US gal/min) 
    336E / 336F  578 L/min (152.7 US gal/min) 
    329E / 329F / 330F  494 L/min (130.5 US gal/min) 
    326F  462 L/min (122.0 US gal/min) 
    324E  462 L/min (122.0 US gal/min) 
    323E / 320E / 320E N / 323 E N / 320E RR  428 L/min (113.1 US gal/min) 
    320F / 323F N  422 L/min (111.5 US gpm) 
    323F  418 L/min (110.4 US gpm) 
    318E / 316E / 318F / 316F  300 L/min (79.3 US gal/min) 
    314E CR / 314F / 315F  256 L/min (67.6 US gal/min) 
    312E / 312F / 313F  256 L/min (67.6 US gal/min) 

  2. Work tool open and close speed can be decreased by lowering the following parameter value.

    1. Spool shift pressure adjustment to extend the attachment control valves.

      "Atch #1 Max Ext Press" (Parameter #30) - XXXX [kPa]

      "Atch #2 Max Ext Press" (Parameter #40) - XXXX [kPa]

      Note: For reference, this parameter is set within the range of 800 kPa to 2000 kPa. A parameter setting for spool shift pressure of 0 kPa is not made for flow from two pumps.

Pump Flow to the Work Tool (Multiple Operation)

One Pump Flow

  1. Set the additional flow to the work tool when multiple operations are to take place by using the following parameter settings.

    "Atch #1 Mult-Ope Add Flow Setting" (Parameter # 28) - XXX [L/min]

    Note: Pump flow to the work tool may exceed the upper limit flow set (Parameter #27) when setting additional flow for multiple operation.

  2. Setting the following parameters will enhance the work tool operation along with other implement movement.

    1. Spool shift pressure adjustment to extend the attachment control valve.

      "Atch #1 M-Ope Max Ext Press" (Parameter #32) - XXXX [kPa]

Note: For reference, this parameter is set within the range of 800 kPa to 2000 kPa.

Two Pump Flow

  1. Set the additional flow to the work tool when multiple operations are to take place by using the following parameter settings.

    "Atch #1 Mult-Ope Add Flow Setting" (Parameter # 28) - XXX [L/min]

    Note: Pump flow to the work tool may exceed the upper limit flow set (Parameter #27) when setting additional flow for multiple operation.

  2. Setting the following parameters will enhance the work tool operation along with other implement movement.

    1. Spool shift pressure adjustment to extend the attachment control valve.

      "Atch #1 M-Ope Max Ext Press" (Parameter #32) - XXXX [kPa]

      "Atch #2 M-Ope Max Ext Press" (Parameter #42) - XXXX [kPa]

      Note: For reference, this parameter is set within the range of 800 kPa to 2000 kPa. A parameter setting for spool shift pressure of 0 kPa is not made for flow from two pumps.

Enhanced Multiple Operation for Two Pump Flow

When operating the work tool with combined pump flow along with other functions (boom, stick, and swing), the control of the work tool can be improved using the following.

Note: This parameter setting is only available when "Multi Ope Atch Valve Limit" (Parameter # 14) is Enabled.

  1. The speed of the work tool when operating multiple functions at the same time can be increased or decreased. Increase the value of parameter to increase the speed. Decrease the value of the parameter to decrease the speed.

    1. Spool shift pressure adjustment to extend the attachment control valve when operating the work tool with Boom UP, Stick IN, and Swing.

      "Single Mode Max Ext Press" (Parameter #15) - XXXX [kPa]

      Set this parameter within the following range.

      • "Single Mode Max Ext Press" (Parameter #15) greater than or equal to "Atch #1/#2 Max Ext Press" (Parameter #30 and #40)

      • "Single Mode Max Ext Press" (Parameter #15) less than or equal to "Atch #1/#2 M-Ope Max Ext" (Parameter #32 and #42)

Caterpillar Information System:

EMCP4.3/4.4 Engine Oil Pressure Warning
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning and Heating System Sensor Operation
307D Excavator Machine System Specifications Cylinder (Thumb)
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Motor (Air Conditioner Control)
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Blower Motor
EMCP4.1/EMCP4.2 Engine Oil Pressure Warning
349E, 349F and 352F Excavators and 349E MHPU Mobile Hydraulic Power Unit Tool Control System Work Tool Parameters - Control Functions
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Evaporator Coil
EMCP4.3/4.4 Custom Text String Programming
EMCP4.3/4.4 Custom Event Is Not Present
EMCP4.3/4.4 Custom Text String Is Not Shown
EMCP4.3/4.4 Kilowatt Relay Programming
349E, 349F and 352F Excavators and 349E MHPU Mobile Hydraulic Power Unit Tool Control System One-Way/One or Two Pump - Electric Control: Parameter Adjustment
349E, 349F and 352F Excavators and 349E MHPU Mobile Hydraulic Power Unit Tool Control System Two-Way/One Pump - Electric Control: Parameter Setting
349E, 349F and 352F Excavators and 349E MHPU Mobile Hydraulic Power Unit Tool Control System Two-Way/One Pump - Electric Control: Parameter Adjustment
3508C, 3512C and 3516C Locomotive Engines Water Connection Group
3508C, 3512C and 3516C Locomotive Engines Water Connection Group
3512B Engine and SPF343, SPS343 and SPT343 Pumpers Auxiliary Water Pump
3500B High Displacement Locomotive Engines Auxiliary Water Pump
CX28 On-Highway Transmission Transfer Gear and Case - Disassemble
C7 Engines for Combat and Tactical Vehicles Maintenance Interval Schedule
CX28 On-Highway Transmission Transfer Gear and Case - Assemble
2010/11/01 New Tube Assembly Is Used for Low-Pressure Return Lines on C175 Generator Set Engines {1252, 1254}
Modifying the Turbocharger Group on Certain 3500 Marine Engines and 797 and 797B Off-Highway Trucks{1052, 1053} Modifying the Turbocharger Group on Certain 3500 Marine Engines and 797 and 797B Off-Highway Trucks{1052, 1053}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.