Procedure for Correctly Lifting Certain C32 Generator Set Enclosures{7002}
- Generator Set:
- C32 GEN SET (S/N: JSJ1-UP)
Introduction
Do not perform any procedure that is outlined in this Special Instruction until you have read and understand the information that is contained in this document.
Installing the Isolator
Follow the installation instructions below in the following situations:
- The final location of the enclosure is being set
- The unit is being operated prior to final installation
- Loosen the isolator adjusting nut (2) the top of the adjusting bolt (1) .
Show/hide table
Illustration 1 | g02170953 |
(1) Adjusting bolt (2) Adjusting nut (3) Grommet (4) Washer (5) Limit stop locknut (6) Spring |
- Turn the adjusting bolt until the spring (6) starts to compress. Leave the adjusting nut at the top of the adjusting bolt.
- Turn the adjusting bolts one full clockwise turn to adjust each isolator in sequence. Repeat this procedure on all of the isolators.
- Periodically check the limit stop locknuts (5) to ensure that clearance between the washer (4) and the rubber grommet (3) is maintained. Stop the adjustment of an isolator only when the top plate has risen just above the blocks.
- Remove all of the shipping blocks (7) .
Show/hide table
Illustration 2 | g02172333 |
(7) 355-7457 Frame Support (8) Base of the generator set (9) Subbase of the enclosure |
Note: Shipping blocks must be in place during transportation.
Note: Shipping blocks must be removed during the operation of the unit.
- Fine adjust the isolators in order to level the equipment.
- Tighten nut to the base of the equipment.
Lifting Instructions
- Use the proper lifting and rigging method to lift the whole enclosure.
- The use of a spreader bar and 4-point lifting is required.
- Care must be taken to ensure that the enclosure is not crushed with using lifting devices.
- The enclosure package must be lifted separately with factory supplied fuel tanks.
Other Instructions
Show/hide table
Illustration 3 | g02173320 |
(10) Drag hook (11) Shipping bracket |
- Shipping brackets (11) are only used for transportation in an ISO container. The brackets can be removed after site installation.
- Drag hooks (10) are only used for removing the enclosure from the shipping container. Do not use the drag hooks to move the enclosure in any other manner.
Caterpillar Information System:
PM3516 Power Modules Parking
C27 and C32 Generator Set Engines Fuel Lines - Remove and Install
CX31 On-Highway Transmission Power Train Retarder Hydraulic Control Valve - Remove and Install
C27 Generator Set Engines Component Location
C27 and C32 Tier 4 Engines Engine Oil Pan
2010/06/17 Concerns for Engines with Seawater Cooling in Oil Polluted Water {1000, 1394}
C13, C15, and C18 Tier 4 Interim Engines Exhaust Balance Valve - Test
C175 Generator Sets Belt Tensioner - Check
C27 Petroleum Generator Set Engines Oil Temperature Is High
C27 Petroleum Generator Set Engines Pressure Sensor - Calibrate
C175 Generator Sets Belts - Inspect/Replace
C27 and C32 Engines for Caterpillar Built Machines Aftercooler - Test - If Equipped
XQ125 Generator Set Trailer - Inspect
3500 Engines Air Lines
3500 Engines Air Lines
C4.4 Industrial Engine Engine - Clean
3500 Engines Air Shutoff
3500 Engines Water Lines - Aftercooler
C175-16 Marine Propulsion Engines Turbocharger Oil Lines
3500 Engines Water Lines
3500 Engines Engine Oil Cooler
3500B Engines for Caterpillar Built Power Modules Cover Group (Front Housing)
2010/10/01 New Fuel Filter Covers and Oil Filter Covers Are Used on Certain Marine Engines {1261, 1308}
C6.6 Industrial Engine Plate Locations and Film Locations