C6.6 Marine Generator Set Caterpillar


Customer Specified Parameters

Usage:

C6.6 C6T
Customer specified parameters allow the engine to be configured to the exact needs of the application.

Customer parameters may be changed repeatedly as a customer's operation changes.

The following information is a brief description of the customer specified parameters. The following parameter values are included with the descriptions:

  • Minimum

  • Maximum

  • Default

Engine Rating Parameter

Rating Number

The rating number is the selected rating within a power rating family. The personality module defines the power rating family. The personality module can contain one to four ratings. The rating number defines the power rating that is used within the power rating family.

Table 1
Minimum     Maximum     Default    
1     4     1    

ECM Identification Parameter

Equipment ID

"Equipment ID" is the identification of the equipment that is assigned by the customer. The "Equipment ID" is only for reference only by the customer. The "Equipment ID" is not required by the Electronic Control Module (ECM).

Table 2
Value     Default    
17 digits
The available characters are dependent on the service tool that is being used.    
Not programmed    

Miscellaneous

Monitoring Mode Shutdowns

"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.

Table 3
Value     Default    
Disabled
Enabled    
Disabled    

J1939 Continuous Fault Handling

Remote Torque Speed Control Enable Status

The "Remote Torque Speed Control Enable Status" parameter determines the way that faults will be handled by the ECM when the "J1939 Torque Speed Control (TSC1)" message is used as a speed request input to the ECM. Programming the "Remote Torque Speed Control Enable Status" to "Enabled" will cause the ECM to display a fault code if a valid TSC1 message is not received by the engine ECM within 30 seconds of the engine starting. If the" Remote Torque Speed Control Enable Status" is programmed to "Disabled", the engine will display a 247-12 Data Link Malfunction immediately after a loss of a TSC1 message. Program "Remote Torque Speed Control Enable Status" to "Enabled" if the ECM will always be receiving a TSC1 message.

Table 4
Value     Default    
Disabled
Enabled    
Disabled    

Configurable Inputs

Overspeed Protection

The "Overspeed Protection" speed is the engine rpm when a shutdown will occur. Overspeed protection is used in order to protect the engine from damage. Overspeed protection must be enabled in "Monitoring Mode Shudowns".

Table 5
Minimum     Maximum     Default    
1500 rpm     2100 rpm     2100 rpm    

Configurable Governor Droop

"Configurable Governor Droop" allows the engine to run in "droop mode" when the genset is operated in parallel with other gensets.

Table 6
Minimum     Maximum     Default    
0 percent     8 percent     0 percent    

User Defined Switch Installation Status

A user defined shutdown switch is an optional switch input. Programming the "User Defined Switch Installation Status" parameter to "Enabled" notifies the ECM that a user defined switch input is present on pin J1:48. If this parameter is programmed to "Enabled" and the user defined shutdown switch closes, the engine will shut down.

Table 7
Value     Default    
Disabled
Enabled    
Disabled    

Caterpillar Information System:

SR5 Electric Power Generation Front Bracket - Remove and Install
SR5 Electric Power Generation End Bracket - Install
SR5 Electric Power Generation End Bracket - Remove
2008/07/01 New Primary Fuel Filters and Fuel Filter Bases are Now Available {1261, 1262, 1263}
2008/06/30 New Primary Fuel Filters are Now Available {1261, 1263}
Replacement of the Double Notch Piston Skirts on C9 Engines{1225} Replacement of the Double Notch Piston Skirts on C9 Engines{1225}
2008/11/03 A New Single Notched Piston Skirt Is Now Used {1225}
C18 Generator Set Model View Illustrations
795F AC and 795F AC XQ Off-Highway Truck Suspension Cylinder Suspension Cylinder (Rear)
C7 On-highway Engine Fuel Injection Pump
C9 On-highway Engine Fuel Injection Pump
C15 and C18 Petroleum Generator Sets Welding on Engines with Electronic Controls
374F Excavator Machine System Solenoid Valve (Auxiliary Control)
C32 Marine Engine Model View Illustrations
793F and 797F Off-Highway Trucks Braking System Using Caterpillar Electronic Technician to Determine Diagnostic Codes
C6.6 Marine Generator Set Customer Specified Parameters Table
C6.6 Marine Generator Set Customer Specified Parameters Worksheet
3408E and 3412E Engines for Caterpillar Built Machines Engine Oil Filter Base
C6.6 Marine Generator Set Magnetic Pickups - Clean/Inspect
G3304B and G3306B Engines Symptom Troubleshooting
3508, 3512, and 3516 Generator Sets Generator Bearing - Replace
New Repair Procedure for the Purge Pump{107P} New Repair Procedure for the Purge Pump{107P}
C32 Petroleum Generator Sets Generator Bearing Temperature - Test/Record
C6.6 Marine Generator Set Coolant Temperature Is Too High - Radiator Cooling System
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.