Illustration 1 | g01261192 |
(5) Gear |
(1) Torque for two studs ... 30 ± 4 N·m (22 ± 3 lb ft)
(2) Torque for four bolts ... 30 ± 4 N·m (22 ± 3 lb ft)
Illustration 2 | g01261196 |
(3) Torque for the regulator ... 17 ± 2 N·m (150 ± 18 lb in)
(4) Torque for three bolts that hold the retainer shaft ... 7.0 ± 0.4 N·m (60 ± 4 lb in)
(6) Torque for the bolt ... 100 ± 5 N·m (75 ± 4 lb ft)
Illustration 3 | g01261220 |
(A) Insert pin to the following depth. ... 5.0 ± 1.0 mm (0.20± 0.04 inch)
(B) Orient the regulator to 10 ± 5 degrees.
Illustration 4 | g01261288 |
(7) Torque for the elbow ... 37 ± 4 N·m (27 ± 3 lb ft)
(C) Orient the elbow to 90 ± 5 degrees.
(8) Torque for the connector ... 22 ± 2 N·m (16 ± 1 lb ft)
(9) Torque for two bolts ... 30 ± 4 N·m (22 ± 3 lb ft)
(10) Torque for two nuts ... 30 ± 4 N·m (22 ± 3 lb ft)
Illustration 5 | g01261298 |
Use the following procedure after the pump has been installed to the housing:
- Torque the plug (12) to 4.5 ± 0.5 N·m (40± 4 lb in).