NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products. Dispose of all fluids according to local regulations and mandates. |
- Disconnect hoses (1) and (6).
- Loosen clamps (2) and (4). Remove hoses (3) and (5).
Show/hide table
Illustration 2 g06306853 - Remove bolts (8) and cover (7).
Show/hide table
Illustration 3 g06306860 - Remove nuts (9) and cover (10).
Show/hide table
Illustration 4 g06306868 - Remove separator assembly (11).
Illustration 1 | g06306543 |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Install separator assembly (11) in the reverse order of removal.
Note: Ensure that the foam damper pads are installed with the separator assemblies.