Boost Pressure Is High
Use this procedure in order to troubleshoot a high boost pressure or use this procedure if one of the following event codes is active. Refer to Troubleshooting, "Event Codes" for information about event codes and the default trip points for these codes. You must access the monitoring system on Caterpillar Electronic Technician (ET) in order to view the current trip points for these codes.
Show/hide table
Event Code | ||
---|---|---|
Description | Default Conditions which Generate this Code | System Response |
E162(1) High Boost Pressure | The boost pressure is above the trip point for high boost pressure. | The code is logged. |
E162(2) High Boost Pressure | The code is logged. The engine power will be derated. |
- Excessive engine load
Reduce the load on the engine.
Caterpillar Information System:
G3500 Generator Sets Parallel Operation
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Sensor Signal (PWM) - Test
C7, C9, C13 and C15 On-highway Engines (California Air Resources Board Idle Reduction Information) Monitoring System - Additional Information for 2008 Caterpillar On-highway Engines which are Regulated by the California Air Resources Board (CARB)
G3500 Generator Sets Electrical System
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) GSC CID 0269 - FMI 03
3500 Engines Air Inlet and Exhaust Lines
2008/02/01 A New Plug and O-ring Are Now Used on the Cylinder Head {1100}
2008/02/25 A New Plug and O-ring Are Now Used on the Cylinder Head {1100}
G3600 Engines Speed Control (Switch) - Test
G3612 and G3616 Engines Prechamber Ignition Body - Install
2007/12/01 A New Internal Wiring Harness for the Injectors is Now Used {1120, 1408}
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Sensor Signal (Analog, Passive) - Test
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Sensor Signal (Analog, Active) - Test
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Parallel Setpoint Programming OP5-3
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Coolant Temperature Is High
G3500 Generator Sets Crankshaft Vibration Damper - Inspect - Fluid Sample
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Coolant Temperature Is Low
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Crankcase Pressure Is High
G3500 Generator Sets Engine Speed/Timing Sensor - Clean/Inspect
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Normal Mode
3516C Generator Set Engine Engine Does Not Crank
G3600 Engines Detonation - Test
C-10 and C-12 Truck Engines Speed/Timing Sensor
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Exhaust Temperature Is High