Usage:
The 5P4149 Conversion Group and 5P4150 Nozzle Testing Group have a 5P4721 Tube with the fittings already installed. But when a replacement 5P4721 Tube is ordered, the tube and fittings must be ordered separately and the tool assembled in your shop. The tube and fittings are shown in Illustration 1.
Illustration 1. 5P4721 Tube and Fittings. Note direction of the fitting sleeves.
Special care is needed in the assembly of this tool. To install the fittings on the tube, use the procedure that follows:
1. Assemble the nut and sleeve on the tube. Install the tube into the fitting and hold it in position until the nut is tightened.
2. During the first assembly of a new tube, tighten the nut only until the edge of the nut is even with the base of the threads on the fitting. Do not tighten beyond this point. (Illustration 2.)
Illustration 2. 5P4721 Tube with fittings installed.