Structural Paint On Lift Arms
Usage:
WHEEL LOADERS938G (6WS),
IT38G (1CW),
950G (2JS, 5FW),
962G (7BW, 3BS) WHEEL LOADERS
IT38G (1CW),
950G (2JS, 5FW),
962G (7BW, 3BS) WHEEL LOADERS
Problem:
No procedure to touchup structured paint was available.
Solution:
Here is the procedure to touchup structured paint for lift arms:
Reference: SIGMA...: UC 5063-3117
Product Description
- - Structured primer based on epoxy-ester resin
- - One pack quick air drying
- - To cover up some manufacturing faults of the surface
- - Chrome and lead free
- - Recoatable by alkyd / acrylic modified alkyd and polyurethane topcoats
- - Good anticorrosion properties
- - One pack quick air drying
How to supply the product
- - SIGMA-COATINGS: Phone 32 (0) 64 51 76 70
- - Available conditioning: 1/2 L / 5 L cans
How to touchup
- - All free particles to be removed
- - Scratched area cleaning:
- * degreasing
- * rinsing
- * blowing up
- * drying
- * rinsing
- - Before use, paint to be correctly agitated
- - Manual application
- * adapted roller or foam sponge
- * viscosity of 35-40 seconds Din 4 at 22 degrees
- * to thin, use xylene or equivalent
- * viscosity of 35-40 seconds Din 4 at 22 degrees
- - Gun application
- * round nozzle with 2,8 and 4,2 mm openings
- * conventional air
- * pression of ± 4 bars
- * conventional air
- - Thickness to be reached: ± 50 microns
- - Air drying (10-15 minutes)
- - Topcoat recovering (20-30 microns)
- - Air drying
- - Scratched area cleaning:
CATERPILLAR BELGIUM WHEEL LOADER TEAM COPYRIGHT 1998 CATERPILLAR ALL RIGHTS RESERVED
Caterpillar Information System:
Brake Oil Cooler Guide Brake Oil Cooler Guide
Clutch Failures And Inadequate Lubrication Of Planetary Group Parts Clutch Failures And Inadequate Lubrication Of Planetary Group Parts
Radiator Guard Cross Rod Failure Radiator Guard Cross Rod Failure
Bolts For New Cab Mounts Are Too Long Bolts For New Cab Mounts Are Too Long
Transmission Neutralization Transmission Neutralization
Wet Steering Clutch Yoke Nonconformance Wet Steering Clutch Yoke Nonconformance
C Frame Hinge Pin Retaining Bolt Loosening C Frame Hinge Pin Retaining Bolt Loosening
6S-5906 Pin May Break During Back Dragging Operations 6S-5906 Pin May Break During Back Dragging Operations
The Speedometer May be Incorrectly Set The Speedometer May be Incorrectly Set
Hard Engine Starting Hard Engine Starting
Mismatched Wiring Harness Pins Mismatched Wiring Harness Pins
Hystat Machines Overheating Hystat Machines Overheating
Computerized Monitoring System Computerized Monitoring System
Cab Air Filter Cab Air Filter
Loss Of Logs From Grapple When Operating Boom Or Arch Functions At Low Engine Speeds Loss Of Logs From Grapple When Operating Boom Or Arch Functions At Low Engine Speeds
Early Hour Clutch Plate And Piston Tang Wear Is Normal Early Hour Clutch Plate And Piston Tang Wear Is Normal
Inspect Sprocket Segment Mounting Bolts Inspect Sprocket Segment Mounting Bolts
High Brass Readings In Power Train Oil System High Brass Readings In Power Train Oil System
Aftercooler Coolant Hose Clamps May Be Incorrectly Tightened Aftercooler Coolant Hose Clamps May Be Incorrectly Tightened
Air Conditioner Leaking Condensation Into Cab Air Conditioner Leaking Condensation Into Cab
Open Rops Heater Relay Open Rops Heater Relay
Wire Harness May Contact The Muffler Support Wire Harness May Contact The Muffler Support
Cracks May Occur In Push Arm Bearing Assembly Welds Cracks May Occur In Push Arm Bearing Assembly Welds
Final Drive Planet Bearings Final Drive Planet Bearings