Removal Procedure
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Disconnect harness assembly (1) .
Illustration 1 | g01068295 |
- Remove fuel temperature sensor (2) from the fuel filter base.
- Remove the O-ring seal from the fuel temperature sensor.
Installation Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Install a new O-ring seal on the fuel temperature sensor.
Illustration 2 | g01068295 |
- Install fuel temperature sensor (2) and tighten to a torque of 20 ± 5 N·m (15 ± 4 lb ft).
- Connect harness assembly (1) .