EMCP3 Caterpillar


Password Entry

Usage:

G3306 07Y
There are three levels of password protection associated with the EMCP 3 control. All of the adjustable parameters are associated with a specific level of security. A specific level of security is required to change each parameter.

The passwords only affect changing parameters from the EMCP 3 control. Changing parameters with Cat ET Service Tool does not require passwords.

The level of password protection that is required for each set point is identified on the parameter set point entry screen. A security level identification number "1", "2", or "3" next to a padlock symbol is displayed on the parameter set point entry screen. Level 3 security is used for the most secure set points and level 1 security is used for the least secure set points.

If the EMCP 3 is currently at the required level of security when viewing a parameter, then the padlock will not appear.

If a parameter is displayed with a padlock, but there is no security level identification number associated with the parameter, then the parameter cannot be changed from the EMCP 3 display.

Level 1 and level 2 passwords are disabled when shipped from the factory. If desired, level 1 and level 2 passwords can be user-defined.

Function and Navigation Keys

Reference: The call outs in this section are related to the EMCP 3 control system panel illustration in the Systems Operation, RENR7902, "Electronic Control Module (Generator Set)" section.

The keys that are listed below are used for programming the EMCP 3 and for navigating within the menu structure.

Reference: Refer to Systems Operation, "Electronic Control Module (Generator Set)" section for an explanation of the function keys and the navigation keys. The function keys include the enter and escape keys. The navigation keys include the scroll left, scroll right, scroll up, and scroll down) keys.

Escape (9) - Used to navigate up (backward) through the menu structure and to back out of data entry screens during set point programming.

Enter key (10) - Select a highlighted menu item or save a programmed value.

Scroll Right key (11) - During numeric data entry, choose the digit to edit. During certain set point adjustments, select or deselect a check box.

Scroll Down key (12) - Move down through the main menu or navigate within a list in order to highlight one of the items. Also used to decrement digits (0-9).

Scroll Up key (13) - Move up through the main menu or navigate within a list in order to highlight one of the items. Also used to increment digits (0-9).

Scroll Left key (14) - During numeric data entry, choose the digit to edit. During certain set point adjustments, select or deselect a check box.

Drop to Minimum Security Level

The first option on the security screen is "DROP TO MIN LEVEL". This option refers to a process of placing the EMCP 3 into the lowest level of security that is authorized. The lowest level of security would be used after the programming of the control is complete. If "DROP TO MIN LEVEL" is not initiated manually, then the control will automatically revert to the minimum level after 10 minutes of non-activity.

  1. From the "MAIN MENU", press the up key or the down key in order to highlight "CONFIGURE".

  2. Press the enter key in order to select "CONFIGURE". "SECURITY" will be highlighted.

  3. Press the enter key in order to select the "SECURITY". The "DROP TO MIN LEVEL" option will be highlighted.

  4. Press the enter key in order to select the "DROP TO MIN LEVEL" option.

  5. The EMCP 3 will now be at the minimum level of security.

Note: When the "SECURITY" screen is displayed, the current level of security for the EMCP 3 is shown at the top of the display screen.

Enter Level 1 or 2 Password

  1. From the "MAIN MENU", press the up key or the down key in order to highlight "CONFIGURE".

  2. Press the enter key in order to select "CONFIGURE". "SECURITY" will be highlighted.

  3. Press the enter key in order to select the "SECURITY" menu. "DROP TO MIN LEVEL" will be highlighted.

  4. Press the down key in order to highlight "ENTER LEVEL 1 OR 2".

  5. Press the enter key in order to select the "ENTER LEVEL 1 or 2" menu. "ENTER PASSWORD FOR DESIRED LEVEL" is displayed. There is also a 16-digit entry field with 0 highlighted at the far right.

  6. Press the up key or the down key in order to increment or decrement the highlighted digit to the desired number.

  7. Press the left key in order to highlight the next character to be entered. Press the up key or the down key in order to increment or decrement the highlighted digit to the desired number.

  8. Continue this process until the correct password has been entered for the corresponding level. When all digits of the password are correctly entered, then press the enter key. This action will display the current level of password protection and the parameters can now be set.

Note: The EMCP 3 will go to the highest level of security authorized by a correctly entered password.

Note: Level 1 and level 2 passwords are entirely determined by the user and can range from one to 16 digits.

Note: If parameters are being changed using a Cat ET Service Tool, then a password is not required.

Enter Level 3 Password

The level 3 password is intended for situations where a customer or a dealer wants to do something that would typically be done with the service tool, but the service tool is not available.

  1. From the "MAIN MENU", press the up key or the down key in order to highlight "CONFIGURE".

  2. Press the enter key in order to select "CONFIGURE". "SECURITY" will be highlighted.

  3. Press the enter key in order to select "SECURITY". "DROP TO MIN LEVEL" will be displayed.

  4. Press the down key in order to highlight "ENTER LEVEL 3". Press the enter key in order to select "ENTER LEVEL 3".

  5. A 16 - digit number will be displayed and "ENTER RESPONSE" will be highlighted. Make a copy of the 16 - digit number that is displayed. Work through the dealer "Technical Communicator" to contact the "Dealer Solutions Network" (DSN) in order to obtain a factory provided response code. The factory provided response code will be entered into the EMCP 3.

  6. When the factory response is received from the factory, press the enter key in order to select "ENTER RESPONSE". "ENTER RESPONSE" will be displayed along with a 16 - digit entry field where the factory provided password will be entered. Use the following steps to enter the factory provided password.

  7. Use the up key or the down key in order to increment or decrement the highlighted digit to the desired number.

  8. Press the right key or the left key in order to highlight the next character that is to be entered. Repeat Step 7.

  9. Continue the process in Step 7 and Step 8 until all 16 digits of the password are entered. Press the enter key after all 16 digits of the password are entered. After the password has been entered and after the enter key has been pressed, the current level, "LEVEL 3", of security will be displayed. The parameters can be set at this time.

Note: If parameters are being changed using Cat ET service tool, then a password is not required.

Change Level 1 or Level 2 Password

  1. From the "MAIN MENU", press the up key or the down key in order to highlight "CONFIGURE".

  2. Press the enter key in order to select "CONFIGURE". "SECURITY" will be highlighted.

  3. Press the enter key in order to select "SECURITY". "DROP TO MIN LEVEL" will be highlighted.

  4. Ensure that the current level of security is at least as high as the level of the password that is to be changed.

  5. Press the down key in order to highlight "CHANGE LEVEL 1 PSWD". Press the enter key in order to select "CHANGE LEVEL 1 PSWD". "CHANGE LEVEL 1 PSWD" is displayed along with a 16 - digit password entry field that has a zero highlighted in far right of the field. Use the following steps to enter the password.

  6. Use the up key or the down key in order to increment or decrement the highlighted digit to the desired number.

  7. Press the left key in order to highlight the next character that is to be entered. Repeat Step 6.

  8. Continue the process in Step 6 and Step 7 until the desired password is displayed. Once the desired password is displayed, press the enter key. The password is now set.

Note: In order to change a level 2 password, substitute "CHANGE LEVEL 2 PSWD" for "CHANGE LEVEL 1 PSWD" in step 5 above.

Note: Level 1 and level 2 passwords are entirely determined by the user and can range from one to 16 digits.

Note: To disable a password, set the password to a single zero.