C1.5 and C2.2 Generator Caterpillar


Exciter Field - Flash

Usage:

C2.2 TAG
Self-excited generators may lose the residual magnetism that normally exists in the exciter field and the main field. Residual magnetism is necessary to start the generation process. The magnetism can be restored by flashing exciter field with direct current. A 12 VDC battery can be used to supply the direct current.

Connect the 12 V battery to terminals "E+" and "E-" on the voltage regulator for 2 to 3 seconds. Connect the "+" battery terminal to the "E+" terminal on the voltage regulator and connect the "-" battery terminal to the "E-" terminal on the voltage regulator.

Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.