CPT372 Truck Mounted Pumper Caterpillar


Manual Stop Procedure - Deck Engine

Usage:

CPT372 1WZ


NOTICE

Stopping the engine immediately after the engine has been operating under a load can result in overheating and accelerated wear of the engine components.

Allow the engine to gradually cool before stopping the engine.


There may be several ways to stop the deck engine. Ensure that the stopping procedure is understood. Use the following guidelines for stopping the deck engine.

For additional switch information, refer to this Operation and Maintenance Manual, "Control Panel".

  1. Disengage the driven equipment. Unload the triplex pump.

  1. Set the gear selector to the NEUTRAL position.

  1. Increase the speed of the deck engine. The speed must be between 1000 and 1200 rpm. Run the deck engine at no load for 5 to 10 minutes. This will allow the following situations to occur:

    • The lubricating oil will carry the heat away from the turbochargers. This will prevent premature bearing failure.

    • The engine coolant will distribute heat from the engine evenly through the cooling system. This will prevent cracks in the cylinder heads.

  1. Decrease the speed of the deck engine to low idle.

  1. Permit the deck engine to idle for at least one minute.

  1. Depress the "DECK ENGINE SHUTDOWN" switch in order to stop the deck engine.

  1. Move the "REAR PUMP PROX. RATE" switch to the OFF position.

  1. Ensure that both the deck engine and the truck engine are stopped. Move the "MASTER" switch to the OFF position.

Caterpillar Information System:

C-9 Engine for TK711, TK721, TK722, TK732, TK741, TK751, and TK752 Track Feller Bunchers Engine Speed/Timing Sensor - Calibrate
2002/03/01 A New Gasket Is Used In Turbocharger Groups {1059}
N3 Series Brushless Alternators Normal Operation
3500 Industrial Engines Pressure Switch
C-9 Engine for TK711, TK721, TK722, TK732, TK741, TK751, and TK752 Track Feller Bunchers CID 0164 FMI 04 Injector Actuation Pressure voltage low
Procedure for Diagnosing the HEUI Fuel System {7729} Procedure for Diagnosing the HEUI Fuel System {7729}
CPT372 Truck Mounted Pumper Manual Stop Procedure - Truck Engine
307D, 311D, 312D, 313D, 315D, 318D, 319D, 320D, 323D, 324D, 325D, 326D, 328D, 329D, 330D, 336D, 340D, 345D, 349D, 374D, 390D and M325D Excavators Air Conditioning and Heating Refrigerant Compressor
2005/03/01 Check the Calibration of the Wastegate Actuator in order to Diagnose a Low Boost Condition {1052, 1057}
3618 Engine Engine Shutdown
3618 Engine Thermocouples - Main Bearings
3618 Engine Detectors
3500 Industrial Engines Pressure Switch
G3600 Engines Troubleshooting Data Sheet
3500 Generator Set Engines Pressure Switch
3054E and 3056E Industrial Engines Engine Description
CPT372 Truck Mounted Pumper Starting the Engine
3500 Generator Set Engines Pressure Switch
3500 Industrial Engines Ammeter
3054E and 3056E Industrial Engines Reference Material
3054 and 3056 Industrial and Generator Set Engines Connecting Rod
3406E, C12, C15 and C18 Marine Engines System Configuration Parameters
3500 Generator Set Engines Ammeter
N3 Series Brushless Alternators Field Winding - Test