Electronic Modular Control Panel II (EMCP II) Caterpillar


GSC CID 0248 - FMI 09 (for EUI Engines)

Usage:

3406B 4JK
Conditions Which Generate This Code:

This diagnostic code is associated with the CAT Data Link. The FMI 9 means that the ECM has determined that an abnormal update has occurred.




Illustration 1g00485981

On EUI engines, the GSC uses the CAT Data Link in order to communicate with the engine ECM. The CAT Data Link consists of two wires that connect the GSC to the engine ECM.

The possible causes of a CID 248 FMI 9 are listed below.

  • A short to the battery positive terminal ("B+") of either of the two CAT Data Link wires

  • A short to the battery negative terminal ("B-") of either of the two CAT Data Link wires

The GSC cannot detect an open in the circuit of the CAT Data Link. The GSC treats a CID 248 FMI 9 as an alarm fault. Active alarm faults are shown on the display when the "Alarm Codes" key is pressed. The engine control switch (ECS) is in any position except the OFF/RESET position. Troubleshoot and repair the wiring. See Testing And Adjusting, "Schematics And Wiring Diagrams". Clear the fault from the fault log after troubleshooting is complete.

Test Step 1. CHECK THE BATTERY POSITIVE TERMINALS

  1. Ensure that there are not shorts between the +battery and either of the CAT Data Link wires.

  1. Turn the ECS to OFF/RESET.

  1. Disconnect both cables from the battery.

  1. Measure the resistance between the positive battery cable and both CAT Data Link wires.

Expected Result:

The resistance between the positive battery cable and both of the CAT Data Link wires should be greater than 5000 ohms.

Results:

  • OK - The resistance between the disconnected positive battery cable and either of the CAT Data Link wires is greater than 5000 ohms. Proceed to Test Step 2.

  • NOT OK - The resistance between the disconnected positive battery cable and either of the CAT Data Link wires is less than 5000 ohms.

    Repair: Troubleshoot and repair the wiring. Repair any shorts between the +battery and the CAT Data Link wires. Refer to Testing And Adjusting, "Schematics And Wiring Diagrams".

    Stop.

Test Step 2. CHECK THE BATTERY NEGATIVE TERMINALS

  1. Ensure that there are no shorts between the battery negative terminal and either of the CAT Data Link wires.

  1. Turn the ECS to OFF/RESET.

  1. Disconnect both cables from the battery.

  1. Measure the resistance between the negative battery cable and both CAT Data Link wires.

Expected Result:

The resistance between the negative battery cable and both of the CAT Data Link wires should be greater than 5000 ohms.

Results:

  • OK - The resistance between the disconnected negative battery cable and either of the CAT Data Link wires is greater than 5000 ohms. Stop.

  • NOT OK - The resistance between the disconnected negative battery cable and either of the CAT Data Link wires is less than 5000 ohms.

    Repair: Troubleshoot and repair the wiring. Repair any shorts between the disconnected negative battery cable and the CAT Data Link wires. Refer to Testing And Adjusting, "Schematics And Wiring Diagrams".

    Stop.

Caterpillar Information System:

3500 Generator Set Engines Jacket Water Heater
CPT372 Truck Mounted Pumper Specifications
C12 Marine Engine Engine Valve Lash - Inspect/Adjust
CIPI UNDERCARRIAGE Arrangements: 3Q6662, 6Z7861, 6Z7885, 6Z7947, 6Z7957, 6Z7999, 9Q5044, 9Q5065, 9Q5082, 9Q5090, 9Q5093, 9Q5115, 9Q5118, 9Q5126, 9Q5135, 9Q5141, 9Q5168, 9Q5175, 9Q5206, 9Q5255, 9Q5259, 9Q5268, 9Q5412, 9Q5436, 9Q5464, 9Q5514, 9Q5617, 9 Recoil Spring - Assemble
Electronic Modular Control Panel II (EMCP II) GSC CID 0190 - FMI 03
Electronic Modular Control Panel II (EMCP II) GSC CID 0190 - FMI 02
SR4 Generator with VR3 or VR4 Voltage Regulator Rotor - Remove and Install
SR4 Generator with VR3 or VR4 Voltage Regulator Generator - Align
3054 and 3056 Marine Generator Set Engines Air Inlet Heater - Remove and Install
Electronic Modular Control Panel II (EMCP II) GSC CID 0168 - FMI 04
Electronic Modular Control Panel II (EMCP II) GSC CID 0168 - FMI 03
SR4 Generator with VR3 or VR4 Voltage Regulator Generator - Install
Electronic Modular Control Panel II (EMCP II) GSC CID 0268 - FMI 02
Electronic Modular Control Panel II (EMCP II) GSC CID 0269 - FMI 03
Electronic Modular Control Panel II (EMCP II) GSC CID 0269 - FMI 04
3408E and 3412E Industrial Engines Air Starting Motor
Electronic Modular Control Panel II (EMCP II) GSC CID 0333 - FMI 03
C0.5, C0.7, C1.1/3011C, C1.5/3013C, C1.6 and C2.2/3024C/3024CT Industrial Engines and Engines for Caterpillar Built Machines Piston Height - Inspect
Electronic Modular Control Panel II (EMCP II) GSC CID 0333 - FMI 04
C12 Marine Engines Engine Rating Definitions
3054 and 3056 Marine Generator Set Engines Heat Exchanger - Disassemble - 3054 Engine
Electronic Modular Control Panel II (EMCP II) GSC CID 0334 - FMI 03 (for EUI Engines)
3054 and 3056 Marine Generator Set Engines Heat Exchanger - Assemble - 3054 Engine
3500 Generator Set Engines Turbocharger
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.